Technical data DM50NTE
22
12 Technical data
The refrigerant circuit contains R134a.
Contains fluorinated greenhouse gases
Hermetically sealed equipment
DM50NTE D DM50NTE F
Voltage: 100 – 240 Vw, 50 – 60 Hz
Cooling capacity: max. 21 °C below ambient temperature
(adjustable in three steps: 5 °C, 7 °C, 12 °C)
Category: 2 (Cellar)
Gross capacity: 50 l
Capacity: 45 l
Energy efficiency class: A+
Power consumption: 91 kWh/annum
Climatic class: N
Ambient temperature: +16 °C to +32 °C
Noise emission (sound power): 0 dB(A)
Refrigerant quantity: 64 g
CO
2
equivalent: 0.092 t
Global warming potential (GWP): 1430
Dimensions main drawer W x D x H: 430 x 330 x 302 mm
Dimensions mini drawer W x D x H: 159 x 285 x 88 mm
Dimensions W x D x H (see also
fig. 7, page 6):
550 x 517 x 418 mm 550 x 487 x 418 mm
Weight: 23.5 kg 23.0 kg
Inspection/certification:
DM50NTE-IO-16s.book Seite 22 Dienstag, 28. Februar 2017 3:33 15