SinePower Troubleshooting
17
11 Troubleshooting
!
I
The LED (fig. 2 2) indicates the fault:
WARNING!
Do not open the device. You risk sustaining an electric shock by doing
this.
NOTE
If you have detailed questions on the specifications of the inverter
please contact the manufacturer (addresses on the back of the instruc-
tion manual).
LED display Cause Remedy
Quick flash Input voltage is
too high
Check the input voltage and reduce it.
Input voltage too
low
The battery needs recharging.
Check the cables and connections.
2 s lit, short
interruption
Overheating Switch off the inverter and the consumer.
Wait 5 to 10 minutes and switch the inverter on again
without any electric consumers.
Reduce the load and make sure the inverter has better
ventilation. Then switch the consumer back on.
Excessive load Switch off the inverter and remove the consumer.
Then switch the inverter back on without the con-
sumer. If no excessive load is now shown, then there
is a short circuit in the consumer or the total load was
higher than the power specified on the data sheet.
Check the cables and connections.
Off Other fault Contact the service.
DSP600-2000--IO-16s.book Seite 17 Montag, 7. Mai 2018 1:39 13

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dometic DSP612 and is the answer not in the manual?

Dometic DSP612 Specifications

General IconGeneral
BrandDometic
ModelDSP612
CategoryInverter
LanguageEnglish

Related product manuals