Connecting the inverter SinePower
12
8 Connecting the inverter
8.1 General instructions
!
• When installed in vehicles or boats, the inverter must be connected to the chassis
or earth.
• When setting up a socket distribution circuit (mains setup), comply with the
applicable regulations.
• Only use copper cables.
• Keep the DC cables as short as possible (< 1 m).
• Keep to the specified cable cross section and fit a cable fuse (fig. 7 1) as close
to the battery as possible on the positive cable (see the table).
WARNING!
• The inverter may only be connected by a qualified workshop. The
following information is intended for technicians who are familiar
with the guidelines and safety precautions to be applied.
• Never use the inverter on vehicles where the positive terminal of the
battery is connected to the chassis.
• If you do not fit a fuse to the positive cable, the cables can over-
load, which might result in a fire.
Device
Required cable
cross section
Cable fuse
DSP612 25 mm² 150 A
DSP624 25 mm² 150 A
DSP1012 35 mm² 200 A
DSP1024 25 mm² 150 A
DSP1512 50 mm² 250 A
DSP1524 25 mm² 150 A
DSP2012 70 mm² 300 A
DSP2024 35 mm² 200 A
DSP600-2000--IO-16s.book Seite 12 Montag, 7. Mai 2018 1:39 13