PRODUCT CARE
CLEANING
Always keep the refrigerator clean. Cleaning the refrigera-
tor is usually done after it is defrosted or put into storage.
Use lukewarm weak soda solution to clean the interior
liner of the refrigerator. Use warm water only to clean the
nned evaporator, gasket, ice tray and shelves. Do not
spray liquids near electrical outlets, connections or the
refrigerator components.
To keep the refrigerator operating effi ciently and safely,
periodic inspection and cleaning of several components
once or twice a year is recommended:
Check the lower vent, upper vent and area between
these openings for any obstructions such as bird/insect
nests, spider webs, etc.
Make sure the refrigerator area is free from combusti-
ble material, gasoline and other fl ammable vapors or
liquids.
Clean the coils on the back of the refrigerator. Use a
soft bristled brush to dust off the coils.
CAUTION
Before replacing the lamp, turn off the refrig-
erator. Wear gloves as protection against hot
lamp, broken glass as protection of the new
lamp.
6
!
CAUTION
Never use strong chemicals or abrasives to
clean these parts, as the protective surfaces
will be damaged.
DM2652, DM2662, DM2663, DM2852 & DM2862
1 2
54
3
Use the Airing Position
Card to keep the doors ajar
if the refrigerator will not be
in use for an extended period
of time or put in storage.
AIRING POSITION CARD
REPLACING THE HALOGEN LAMP
DM3862 & NDM1062
DM3862 & NDM1062
The lamp is located at the top of the refrigerator compartment.
To replace the lamp, follow these steps:
Remove the lamp cover. 1.
Wearing gloves, pull out the lamp from socket. Re-2.
place it with a new 12V, 10W halogen lamp base G4.
Put back the lamp cover.3.
Turn the gear counterclockwise, when the hold 9.
switch closes, the mold assembly will continue
to operate through the harvest cycle. During the
water ll sequence of the harvest cycle the com-
pressed air will blow out the water trapped in the
solenoid valve.
Repeat the harvest cycle operation several times.10.
Up to 20 PSIG air pressure can be used to clear the
solenoid valve. Damage to solenoid can occur if
AC power is applied for more than 20 seconds.
Make sure that the metal tube is in the plastic 11.
water line to the ice maker. Reconnect and tighten
lines on water solenoid valve. Leave the water
supply turned off until temperatures are above
0°F/-18°C
Dry the ice maker mold assembly with a soft 12.
cloth.
Place bail arm in the “UP/OFF” position.13.