Configuring the system software RTX1000/2000, SPX1200T
12
8 Configuring the system software
Before the system is first put into operation, the control unit settings can be
adjusted to suit the various installation conditions. Those adjustments must be
made by the installer (fig. 5).
I
8.1 Entering and exiting configuration mode
➤ Press and hold the button.
➤ Press and hold the button for longer than 3 s.
✓ The display shows the symbol .
✓ The parking cooler switches to configuration mode.
✓ The display shows “P.01” and the symbol flashes.
➤ Scroll through the menu by pressing the or button to select the
desired menu item.
➤ Press the button to open the desired menu item.
➤ Press and hold the button for longer than 3 s to exit configuration mode.
Display
indication
Parameter Meaning
Factory
setting
P.01 Low voltage
shut-down
The battery monitor shuts down the
system at the voltage defined here.
22.8 V
P.02 Unit for tempera-
ture display
The temperature can be displayed in
°C or °F.
°C
P.05 Tilt sensor The tilt sensor can be calibrated to a
zero setting.
–
NOTE
Configuration mode can still be activated if the low voltage cut-out has
switched off the system and only residual voltage is available.