Maintenance Schedule
REGULAR SERVICE PERIOD
Performed at every indicated month or
operating hour interval, whichever comes.
first.
Each
use
First
month or
20 Hrs.
Every 3
months or
50 Hrs.
Every 6
months or
100 Hrs.
Every
yea
r or
150 Hrs.
ITEM
Engine oil
Check level
O
Change
O
O
Sediment Cup Clean
O
Spark plug
Check-Clean
O
Replace
O
Idle speed Check-Adjust
O
(1)
Valve clearance Check-Adjust
O
(1)
Fuel tank and filter Clean
O
(1)
Combustion chamber Clean After every 150 Hrs.
Fuel line Check Every 2 years (Replace if necessary)
Emission-related items.
1 These items should be serviced by your servicing dealer unless you have the proper tools and are mechanically
proficient. Refer to manual for service procedures.