Master
Code by default is 1234
Installer
Code by default is 5555 - (Do not ever lose this number, this is your only way
into programming. If you change it, you better remember it.)
You will always enter into programming by pressing *8 and the
installer
co
d
e (5555).
Taking the Sample Alarm Kit above and using the common Zone Definitions, here is what
we want to do with the system. We will make the Front Door sensor delayed in zone 01,
the Smoke Alarm will be standard 24 hour monitoring in zone 02, the Bedroom Window
Sensor we will have instant arming and disarming in zone 03. The
Living Room
Motion
will be an Interior device that will have a stay/away capabilities in zone 04.
Desc
r
i
p
t
io
n
:
Type of
Del
a
y
:
Zone #
Z
o
n
e
Type
Front Door Sensor Delay 01 0
1
Smoke Alarm 24 hour Std, wireless 02 88
Bedroom Window Sensor
Instant
03 03
Living Room Motion Interior Stay/Away 04 05
Here is a list of the most common Zone Definitions:
Definition 01 = Delay 1 (ie: door with a certain time of delay)
Definition 02 = Delay 2 (ie: door with a different delay time)
Definition 03 = Instant (ie: window sensors or doors that do not need a delay)
Definition 05 = Interior Stay/Away (This setting is usually for motions. The
motion is bypassed if a delay zone is triggered, giving you the ability to walk in
front of the motion to get to a keypad. This will also bypass your motion if you are
staying “stay” home.)
Definition 88 = Standard 24hr Fire (wireless)
Set Date and
T
i
m
e
P
r
ess
*6 to set the time, next enter your master code (1234 is default), then press
1. You will enter the four digit time in 24 hour format (military time) then enter
the six digit date example: So if it is 2:30p on October 21, 2008, you would enter 1430
102108, the system will then beep and you would then hit # # # .
Adding Zone Definitions
(Program
Section 001),
We will begin adding our Zone Definitions and will use the above chart for reference and
we will go straight down the list which begins with Zone Number 01. We will only enter
the definitions. After each two-digit definition, the system will beep and automatically want
the definition for the next zone. You will not enter zone numbers here, only definitions, and
those must be entered in order starting with the first definition. By default, the keypad will
display default zone definitions, ignore these numbers and enter you own. Hit # # # to
exit.
Created by:
Alarm System Store
http://alarmsystemstore.com
Created by:
Alarm System Store
http://alarmsystemstore.com

Other manuals for DSC ALEXOR

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the DSC ALEXOR and is the answer not in the manual?

DSC ALEXOR Specifications

General IconGeneral
BrandDSC
ModelALEXOR
CategorySecurity System
LanguageEnglish

Related product manuals