8
Trouble Conditions
When a trouble condition is detected, the Trouble ( ) or System indicator will turn on, and the key-
pad will beep every 10 seconds. Press the key to silence the beeps. Press to view the
trouble condition. The Trouble ( ) or System indicator will flash. The corresponding trouble will be
represented by numbers 1-8.
Alarm Memory
When an alarm occurs, the Memory or System indicator (and Fire indicator, if applicable) will turn on.
To view which sensor(s) generated the alarm, press . The Memory or System indicator and cor-
responding sensor number will flash (i.e. sensor 3).
For the PK5500/RFK5500 keypad use the scroll keys to view the sensors in alarm memory.
Press to exit. To clear the memory, arm and disarm the system.
If an alarm sounded while armed, the keypad will automatically go to alarm memory when you dis-
arm the system. In this instance, you should approach with caution, as the intruder may still be within
the building/premises.
Door Chime (Entry/Exit Beeps)
To turn the door chime function on or off, press and hold the Chime key ( ) for 2 seconds or
press .
LED/
DIGIT
Trouble
Condition
Comments Action
1 Service Required
(Press [1] for
more informa-
tion)
(1) Low Battery (2) Bell Circuit (3) System Trouble (4)
System Tamper (5) Module Supervision (6) RF Jam
Detected (7) PC5204 Low Battery (8) PC5204 AC Fail-
ure
Call for service
2
Loss of AC Power
If the building and/or neighbourhood has lost electri-
cal power, the system will continue to operate on
battery for several hours.
Call for service
3 Telephone Line
Fault
The system has detected that the telephone line is
disconnected.
Call for service
4
Failure to Com-
municate
The system attempted to communicate with the
monitoring station, but failed. This may be due to
Trouble 3.
Call for service
5
Sensor (or Zone)
Fault
The system is experiencing difficulties with one or
more sensors on the system. Press 6 to display the
zone.
Call for service
6 Sensor (or Zone)
Tam p e r
The system has detected a tamper condition with one
or more sensors on the system.
Call for service
7
Sensor (or Zone)
Low Battery
If the system has been equipped with wireless sen-
sors, one or more has reported a low battery condi-
tion.
Call for service
8
Loss of Time &
Date
If complete power was lost (AC and Battery), the time
and date will need to be re-programmed.
Re-program
Time & Date
(page 6)