~26~
3.5 Installation and Leveling
3.5.1 Tools: adjust screw by screwdrivers , Allen wrench
3.5.2 The main machine is calibrated by level gauge to hundredth precision
3.6 Power Supply Requirement
Insufficient voltage from factory power source may affect the power output of the motor and the function of
the controller.
It is important to connect this machine to the correct voltage in the factory power source. Use only an
independent power source.
Table for power supplies requirement:
Model Kw Voltage Current Breaker capacity Wire size
DB-280 9.7Kw 220V 13A 50A 2.08mm²
DB-200 9.7Kw 220V 13A 50A 2.08mm²
DB-660 1.75kw 220V 15A 50A 2.08mm²
DB-700 1.80kw 220V 18A 50A 2.08mm²
3.7 External Power Connection
1. Connect the machine to a dedicated power outlet. Never connect the machine to a power outlet servicing other
appliances or electrical devices.
2. Place the machine close to the power outlet. Do not use extension cords. Use the machine only where voltage is
relatively constant.
3. The range of power supplies for proper operation of the machine.
Tolerance of power supply: LOCAL VOLTAGE 110V or 220V 10%
Frequency fluctuation: 110 V @ 60Hz 10% or 220V @ 50Hz 10%