Chengdu Ebyte Electronic Technology Co.,Ltd. E90-DTU (433L33)-V8_User Manual_EN
Copyright ©2012–2022,Chengdu Ebyte Electronic Technology Co.,Ltd 8
RS-485 interface, interface B
The RS-485 interface B is connected to the
device interface B
RS-485 interface, interface A
The RS-485 interface A is connected to the device
interface A
★ Note: The transceiver will be in poor communication when connected to multiple devices , it is recommended to be
connected to a single device, please try to use parallel 120Ω resistor between 485_A terminal and 485_B.
5. Technical indicators
5.1. Model specifications
Strong penetration
,
anti - interference
To the environment with small data,
long distance, many obstacles
★ Note: Test condition: in clear and open air without shelters, 12V /2A power supply, 5dBi gain sucker antenna over 2
meters height from the ground, with the factory default parameters.
5.2. General specification parameters
See more at 3.2 Dimension
Standard 50 Ω characteristic impedance
It is recommended to use 12V or 24V
Standard DB9 hole / 3.81 terminal
block
65536 configurable addresses