5.3. Frequency range and channels
Model
Default frequency
Frequency range
Channel spacing
Channels
MHz
MHz
MHz
E90-DTU
(433L33)-V8
433
410~441
1
32half duplex
Note: In the same area when multiple data transceivers are communicating one to one at the same time, it is
recommended to set the channel spacing between each group of data transceivers at 2MHz or more.
5.4. Transmit power level
Model
10mW
25mW
50mW
100mW
E90-DTU (433L33)-V8
Note: The lower the transmit power, the closer the transmission distance, but the working current won’t be declined in
exact proportion ,it is recommended to use the maximum transmit power.
5.5. Air data rate
Model
Default air data
rate
Levels
Air data rate(bps)
bps
bps
E90-DTU
(433L33)-V8
2.4
6
0.3、1.2、2.4、4.8、9.6、19.2
Note: The higher the air data rate, the faster the transmission rate, the transmission distance is also closer; when the
rate meets the requirements, the lower air data rate, the better quality.
5.6. Current parameters
Model
Transmitting current mA
Standby current mA
12V
24V
12V
24V
E90-DTU
(433L33)-V8
134
81
28
28
Note: It is recommended to retain more than 50% of the current margin when selecting the power supply, which
will help the data transceiver to work steadily for a long time.