14
2. Pump primer bulb (B) until fuel is visible and flows freely in the
clear fuel tank return line. Pump bulb an additional 4 or 5 times.
3. Close choke (C) (move choke lever up) and pull starter handle (D)
until engine fires.
4. Open choke (C) and if necessary, restart engine. allow engine to
warm up at idle for several minutes.
NOTE
If engine does not start after 4 pulls, repeat instructions.
STARTING WARM ENGINE
1. Move ignition switch (A) to start, pull starter handle (D) and engine
should start. Do not use choke (C).
NOTE
If engine does not start after 4 pulls, use cold start procedures.
STOPPING ENGINE
1. Release throttle trigger (E) and allow engine to run at idle for a few
minutes.
2. Move ignition switch (A) to "STOP" position.
WARNING DANGER
If engine does not stop, shift choke lever to closed position.
Check and repair ignition switch before starting engine again or
serious personal injury may result.