6. Troubleshooting
6.1 Too low or unstable pressure.
Steps 1 - 6
1
2
6.2 Unsatisfactory foam quality
Steps 1 - 4
1
2
3
4
6.3 No foam
Steps 1 - 7
1
2
3
4
5
6
7
Is there suffi cient water
supply to the system?
Check the water supply.
Call a service technician
Is the foam nozzle fi tted?
Fit a 50/200 foam nozzle.
Is the air supply OK? Adjust on the air regulator.
Is the detergent/disinfec-
tant supply?
Adjust the supply on the
dosage valve.
Call a service technician.
Is the switch in foam
position?
Turn the switch to foam
position.
Is a foam nozzle fi tted? Fit a 50/200 foam nozzle.
Is the dosage valve open?
Open the dosage valve.
Is the air supply con-
nected?
Open the shut-off valve
for air.
Is the fi lter in the hose
from the detergent/
disinfectant container
clogged?
Clean or replace the fi lter.
Is there detergent/disin-
fectant in the container?
Fill detergent/disinfectant
in the container.
Call a service technician