product operating instruction
E.G.O. Germany (E.G.O. Elektro-Gerätebau GmbH)
document id.: 90.60145.653-001-02-A / state: 230 - released
designation: Thermostats 55.xxxxx.xxx / 56.xxxxx.xxx
4.3 Electrical connection
4.3.1 Basic information on the electrical connection
Observe the cross-section, insulation material and circuit diagram according to the type drawing.
Observe national standard information on electrical connection, such as EN 60730.
Make sure that the shape and position of the electrical connection are not changed (e.g. bending).
Ensure permanent low-resistance connection.
4.3.2 Information on the various connection types
Observe the following instructions for electrical connection and earthing of the thermostat:
Screw-connection: Pay attention to the tightening torque and secure fit of the cable.
Connection with clamping bracket (U-shape):
– Only use clamping brackets according to the type drawing.
– Pay attention to the tightening torque and the tight fit of the cable.
Plug connection:
– Ensure that the flat receptacle on the flat plug is firmly seated.
– Do not bend the connection when plugging it in.
4.3.3 Ground the thermostat
1. Depending on the application, assess whether and which components need to be integrated into the
earthing concept.
2. Establish electrical connection.