EasyManuals Logo
Home>Emerson>Desktop>ControlWave Series

Emerson ControlWave Series Quick Start Guide

Emerson ControlWave Series
40 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #7 background imageLoading...
Page #7 background image
Emerson FB2200 Flow Computer Quick Start Guide
D301788X012
March 2019
5
1.
Carbon steel bolts do not require lubrication. Stainless steel bolts are factory-coated with a
lubricant to ease installation. Do not apply any additional lubricant when installing either
type of bolt.
2.
Finger-tighten the bolts.
3.
Torque the bolts to the initial torque value using a crossing pattern. See Table 2 for initial
torque value.
4.
Torque the bolts to the final torque value using the same crossing pattern. See Table 2 for
final torque value.
5.
Verify that the flange bolts protrude through the sensor module before applying pressure.
Table 2: Torque Values for the Flange and Flange Adapter Bolts
Bolt
material
Initial torque
Final torque
Carbon
Steel (CS)
300 in. -lbs.
(33.9 N m)
650 in. -lbs.
(73.4 N m)
Stainless
Steel (SST)
150 in. -lbs.
(16.9 N m)
300 in. -lbs.
(33.9 N m)
Proper Bolt Installation
1
Bolt
2
Sensor module

Other manuals for Emerson ControlWave Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Emerson ControlWave Series and is the answer not in the manual?

Emerson ControlWave Series Specifications

General IconGeneral
BrandEmerson
ModelControlWave Series
CategoryDesktop
LanguageEnglish

Related product manuals