© 2017 Emerson Climate Technologies, Inc.
3
AE21-1355 R4
Instructions Pertaining to Risk of Electrical Shock, Fire, or Injury to Persons
WARNING
ELECTRICAL SHOCK HAZARD
Disconnect and lock out power before servicing.
Discharge all capacitors before servicing.
Use compressor with grounded system only.
Molded electrical plug must be used when required.
Refer to original equipment wiring diagrams.
Electrical connections must be made by qualified electrical personnel.
Failure to follow these warnings could result in serious personal injury.
PRESSURIZED SYSTEM HAZARD
System contains refrigerant and oil under pressure.
Remove refrigerant from both the high and low compressor side before
removing compressor.
Never install a system and leave it unattended when it has no charge,
a holding charge, or with the service valves closed without electrically
locking out the system.
Use only approved refrigerants and refrigeration oils.
Personal safety equipment must be used.
Failure to follow these warnings could result in serious personal injury.
BURN HAZARD
Do not touch the compressor until it has cooled down.
Ensure that materials and wiring do not touch high temperature areas of
the compressor.
Use caution when brazing system components.
Personal safety equipment must be used.
Failure to follow these warnings could result in serious personal injury or
property damage.
CAUTION
COMPRESSOR HANDLING
Use the appropriate lifting devices to move compressors.
Personal safety equipment must be used.
Failure to follow these warnings could result in personal injury or
property damage.
Safety Statements
Refrigerant compressors must be employed only for their intended use.
Only qualified and authorized HVAC or refrigeration personnel are permitted to install commission and
maintain this equipment.
Electrical connections must be made by qualified electrical personnel.
All valid standards and codes for installing, servicing, and maintaining electrical and
refrigeration equipment must be observed.
WARNING
WARNING

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Emerson COPELAND 3DSDR17ME-TFD and is the answer not in the manual?

Emerson COPELAND 3DSDR17ME-TFD Specifications

General IconGeneral
BrandEmerson
ModelCOPELAND 3DSDR17ME-TFD
CategoryAir Compressor
LanguageEnglish

Related product manuals