5 Adjust display orientation (optional)
To improve field access to wiring or to better view the optional LCD display:
1. Loosen the set screw until the transmitter housing can rotate smoothly.
2. First, rotate the housing clockwise to the desired location. If the desired
location cannot be achieved due to thread limit, rotate the housing
counterclockwise to the desired location (up to 360° from thread limit).
3. Re-tighten the set screw.
Rotate the Transmitter HousingFigure 5-1:
Torque 30 in-lb (3 N-m)
H3/32 in.
Note
In high vibration applications, the transmitter housing must be fully
engaged into the sensor module to meet the vibration test specifications.
This is achieved by rotating the transmitter housing clockwise to thread
limit.