1592031000 Univ-R4 GB - r1.1 - 2012.07.23 Universal-R 7/20
6. PARAMETER TABLE and factory default settings
IMPORTANT: Always set parameter “tC” first. As you move “tC” between settings 1 to 7, all non-relevant parameters will be masked. After
setting “tC”, it will be possible to modify all the other relevant parameters.
WARNING!!
Always switch the power OFF and then ON at the end of programming to update any parameter changes.
Make sure you connect the correct number of probes to suit the setting of parameter tC. Failure to do this will cause probe
alarms
tC setting No. Probes Type
1, 2, 3 and 7 1 Room only
4, 5 2 Room + Evaporator 1
6 3 Room + Evaporator 1 + Evaporator 2
Any probe alarms can be cleared by turning off / on the power
Table 3: default controller parameters
Description Label Adjustment Range Factory defaults with parameter “tC” 1- 7
1 = On / Off Thermostat
1
2 = Off cycle defrost
2
3 = Time / time defrost
3
4 = Time / temp defrost
4
5 = Time / temp defrost + fan delay
5
6 = Double evaporator defrost
6
Type (category) of controller