Safety and operating instructions
24 © Construction Tools PC AB | 9800 1594 01 | 2020-03-23
Original Instructions
Cause Remedy By
Inside diameter of tank hose too
small.
Check the inside diameter and change if necessary.
Observe the minimum inside diameter! See section
"Hoses and connections".
Workshop
Return pressure too high. Check and lower the return pressure. Customer Center/
Dealer in your area
Hydraulic oil temperature in the
tank higher than 80°C (176°F).
Check the oil level in the hydraulic tank and top up if nec-
essary.
Check the oil flow. Too high oil flow leads to a higher
working pressure and temperature, and that the oil flows
over the pressure limiter.
Check the cooler function on the carrier.See section
"Preparation before breaking".
Carrier driver
Hydraulic oil pressure too low. Check the pressure, adjust as required. Fit new pressure
relief cartridges if necessary, on carrier and breaker.
Check the installation, check the restrictor, and check the
carrier's pressure. See section "Pressure adjustment".
Workshop
10.5 Operating temperature too high
Cause Remedy By
Oil level in tank too low. Check the oil level and top up oil. Carrier driver or work-
shop
Operation in high outside temper-
ature without oil cooler.
Check oil temperature and install an oil cooler if neces-
sary.
Workshop or Cus-
tomer Center /Dealer