Safety and operating instructions
© Construction Tools GmbH | 33905146 01 | 2019-09-05
Original Instructions
45
7.1 Maintenance schedule
during a shift Check the lubricant film on the shaft of the working tool approx. every 2hours.
Manual lubrication of the working tool approx. every 2 hours.
Monitor the filling level of the grease cartridge of the ContiLube
®
II lubrication sys-
tem and immediately replace an empty cartridge.
daily Check the bolted connections at the adapter plate and tighten as required.
Check the hydraulic lines for leaks.
Check that the pipe clamps on the carrier are tight.
Check the screw connections of the swivel joint covers and tighten as required.
Replace damaged swivel joint covers.
during and after the first 50 oper-
ating hours
Tighten the screw connections daily during the first 50 operating hours.
Replace the oil filter cartridges of the carrier after the first 50 operating hours.
Check the fill pressure of the HP-accumulator during the first operating week.
weekly Check he tensioning bolts and tighten as required.
Check the screw connections and tighten as required.
Check the bolts of the retainer bars for tight fit.
Check that the plugs of the retainer bars are in place and are not damaged. Re-
place any damaged plugs.
Check the adapter plate and the breaker box for cracks.
Visual check of the HP-accumulator.
Check the connecting fittings of the ContiLube
®
II system for leaks.
monthly Check the pressure in the piston accumulator.
after the first three operating
month
Check the fill pressure of the HP-accumulator.
every 500 operating hours Check the oil filter of the carrier and replace as required.
when replacing the working tool,
and at least every 100 operating
hours
Check the working tool for wear.
Check the lower and upper wear bush for wear.
Check that the piston impact surface is not chipped.
Check that the working tool impact surface is not chipped.
Check the working tool for burrs.
Check the retainer bar for burrs.
when performing regular replace-
ment of all hydraulic breaker
seals, and at least every 1,000
carrier operating hours
Replace the o-rings on the fastening screws of the HP-accumulator. (EC165T,
EC180T)
annual Check the fill pressure of the HP-accumulator.
if necessary Replace bent and damaged pipes.
Replace damaged hoses.
Check the pressure in the piston accumulator.
Check the adapter plate bolts for wear.