- Centronics Parallel Interface
PIN SIGNAL I/O DESCRIPTION
1 STROBE- Input Synchronize signal Data received
2~9 DATA0~7 Input/Output Data bit Transmitted 0~7
10 ACK- Output Data receiving completed.
11 BUSY Output Impossible to print of data receiving.
12 PE Output Paper empty
13 SELECT Output Printer status for ON/OFF line
14 AUTO FEED- Input Paper auto feed signal
15 GROUND - System ground
16 GROUND - System ground
- CN 71
18 LOGIC-H - +5V
19~30 GROUND - System ground
31 INIT- Input Initialize
32 ERROR- Output Printer error
33 GROUND - System ground
- CN 43
35 +5V - +5V
36 SELLECT IN- Input Printer select signal
- Ethernet Interface
PIN
SIGNAL
I/O
1
Data Out +
Output Data +
2
Data Out -
Output Data -
3
GND
Ground
4
Data IN +
Input Data +
5
Data IN -
Input Data -
6
N.C
7
N.C
8
N.C