EpsonEngineeringEurope SC‐S30600/610TechnicalGuide Page|11
B4.TensionMeasurement
Note:uncorrecttensionwillmodifythequalityoftheprint.Eachkindofmediahasdifferenttensionvalue.This
settingisalsolinkedto[MediaTension]
Depending on the substrate loaded in the printer, you can activate or deactivate the tension for [RIP Settings]
selected. Periodically is recommended for mostcircumstances andis performedevery 5m. Themeasurement value
will be done according the [Media Tension] setting. If the Te nsion Measurement is turned to Off, the
substrate
systemwillrollmoremediathanneededtoavoidtension.Thiswillresultofalonglengthabovethelengthfeed.
B5.MediaTension
Note:ThissettingislinkedtoTensionMeasurement]
According to Tension Measurement, the sequence will check [Periodically], [Every Page] or [Off] the tension value
selectedinthissection.Youcanchoose from 0(no tension)to40(high tension).Dependingonthe mediatype,we
suggestyoutousethesetensionchartvalues:
Inthecaseyoudon’treallyknowwhatisthebesttensionsettings,pleaserefertothisgenericrule:
‐ Forthinmedia=lowtension
‐ formediummedia=mediumtension
‐ thickandheavymedia=hightension
Reminder:eachtime[RIPSettings]is
selected,allmedialoadedwiththisselectionwillusethesettingsdescribed
above.Formoreoptions,pleaserefertoyourRIPsoftwaretoapplyadditionalmediasettings.
TensionMeasurement
Periodically
EveryPage
Off
[OK]Done[↖]Back
Med iaTen sion
Lv15
Range:Lv0‐40
Current:Lv 15
[OK]Done[↖]Bac k
MediaType TENSION
ThinFilm 5‐10
Polyester,Vi nyl 15‐20
Banne r,Canvas 25‐35