DOWN UNDER SERIES II
7. Error Codes
Code Reason / Solution
E1
Low Voltage
• Please check the source voltage to ensure it is above the cut out. Try
lowering the voltage cut out setting to LOW (refer to page 8).
• The vehicle cabling may be inadequate/unsuitable, please refer to
cable specifications table for correct cable thickness (page 5).
• Try on a dierent power source.
E2
Fan Issue
• Fan is drawing too many Amps (Over 1 Amp).
- Contact EvaKool
E3
Compressor Start Issues
• Unplug for 10 minutes.
• Try on a dierent power source.
• Possible compressor module fault.
- Contact EvaKool
E4
The Compressor Speed is Too Low
• Unplug for 10 minutes.
• Move unit to a lower ambient temperature.
• Clean vents / ensure clear air flow over compressor.
• Reduce product load inside unit.
E5
Ambient Temperature Too High
• Move unit to a lower ambient temperature.
• Clean vents / ensure clear air flow.
• Fan fault.
- Contact EvaKool
E6
Thermistor is Unplugged
- Contact EvaKool
Thermistor is Short Circuited
- Contact EvaKool