8 LT45-en-US_V2.1 6/20
Specifications
Sampling rate 2.5 times per second (digital display)
Display 6-digit LCD with battery icon, measurement overload, and
other function indicators
Sensor (detector) Silicon photodiode with spectral response filter and cosine
correction
Ranges and Resolution
*Above 3999, the LCD uses
smaller digits on the right
side
399.9 0.1 39.99 0.01
3999 1 399.9 0.1
*39999 10 3999 1
*399999 100 *39999 10
Auto-range The meter automatically ranges the display
Accuracy
(1 Fc = 10.76 Lux)
LED light:
± (3% of reading + 3 digits) up to 500 Lux (46Fc)
± (3% of reading) above 500 Lux (46Fc)
Visible Light:
Calibrated to standard incandescent lamp 2856
o
K at an
ambient temperature of 23
o
C
± (6% of Reading + 3 digits)
Angle deviation from cosine
characteristics
(Cosine Angular corrected
per JIS C 1609:1993 and CNS
5119 general A class)
30
±2%
60 ±6%
80 ±25%
LED Types Meter measures white, red, yellow, green, and blue LED light
Operating conditions Temperature: 41 to 104
o
F (5 to 40
o
C); Humidity: < 80% RH
Operation Altitude
Storage Temperature/RH 14 to 140
o
F (-10 to 60
o
C); Humidity: < 70% RH
Battery status indication Battery symbol appears empty when battery voltage reaches critical level
Power supply 9V battery
Auto Power OFF Meter powers down after 5 minutes of inactivity (can be defeated)
Dimensions Meter: 38 x 55 x 130mm)
Sensor: 25 x 44 x 80mm)
Cable length: 1.5m)
Weight Approx. 8.8 oz. (250g) with battery installed