Table 5-1. Specifications (continued)
Operating Ambient Temperature Limits
–40_C to 80_C (–40_F to 175_F)
Stem Travel (DVC5010)
0 to 102 mm (4-inches) maximum
0 to 19 mm (0.75-inches) minimum
Shaft Rotation (DVC5020 and DVC5030)
0 to 90 degrees maximum
Mounting
Designed for direct actuator mounting. For
weatherproof housing capability, the instrument
must be mounted upright to allow the vent to drain.
Weight
Less than 2.7 Kg (6 lbs)
1. Defined in ISA Standard S51.1.
2. Normal m
3
/hour—Normal cubic meters per hour at 0_C and 1.01325 bar, absolute. Scfh—Standard cubic feet per hour at 60_F and 14.7 psia.
Related Documents
This section lists other documents containing
information related to the DVC5000 Series digital
valve controllers. These documents include:
D FIELDVUE
R
DVC5000 Series Digital Valve
Controllers Instruction Manual, Form 5335
D FIELDVUE
R
DVC5000 Series Digital Valve
Controller (Bulletin 62.1:DVC5000)
D Mounting FIELDVUE
R
Instruments on Piston
Actuators (PS Sheet 62.1:FIELDVUE(B))
D FIELDVUE
R
Instrument Split Ranging (PS Sheet
62.1:FIELDVUE(C))
D FIELDVUE
R
Instrument Status Flags on
Rosemount RS3 DCS (PS Sheet 62.1:FIELDVUE(D))
D Proportional Control Loop with FIELDVUE
R
Instruments (PS Sheet 62.1:FIELDVUE(E))
D Using Loop Tuners with FIELDVUE
R
Instruments
(PS Sheet 62.1:FIELDVUE(F))
D Audio Monitor for HART
R
Communications (PS
Sheet 62.1:FIELDVUE (G))
D Guidelines for Manually Tuning FIELDVUE
R
Instruments with Firmware Revision 5 (PS Sheet
62.1:FIELDVUE(H))
D Using the HART
R
Tri-Loop HART-to-Analog
Signal Converter with FIELDVUE
R
Instruments (PS
Sheet 62.1:FIELDVUE(J))
D FIELDVUE
R
HF200 Series HART
R
Filters
Instruction Manual - Form 5380
D Type 2530H1 HART
R
Interchange Multiplexer
Instruction Manual - Form 5407
D FIELDVUE
R
ValveLinkt VL2000 Series User
Guide
All these documents are available from your Fisher
Controls representative or sales office. Also please
visit our website at www.FIELDVUE.com.
This product may be covered by one or more of the following patents (5,451,923; 5,434,774;
5,439,021; 5,265,637) or under pending patent applications.
5
For information, contact Fisher Controls:
Marshalltown, Iowa 50158 USA
Cernay 68700 France
Sao Paulo 05424 Brazil
Singapore 128461
The contents of this publication are presented for informational purposes only, and while every effort has been made to ensure their accuracy, they are not to be construed as warranties or guarantees, express or implied,
regarding the products or services described herein or their use or applicability. We reserve the right to modify or improve the designs or specifications of such products at any time without notice.
Printed in U.S.A.
EFisher Controls International, Inc. 1999; All Rights Reserved
FIELDVUE, ValveLink, Tri-Loop, Rosemount, Fisher, Fisher-Rosemount, and Managing The Process Better are marks owned by Fisher Controls
International, Inc., Fisher-Rosemount Systems, Inc., or Rosemount Inc. HART is a mark owned by the HART Communications Foundation
All other marks are the property of their respective owners.