Power Management
Start engine without anything connected to generator.
When engine has stabilized, plug in and turn on first load. It is strongly recommended to plug in devices with the largest
output first and the smallest output last to help prevent overloading the generator.
Allow generator output to stabilize (engine and attached devices run evenly) before plugging in the next load.
Cold Weather Operation
Under humid conditions where temperatures drop to 40ºF (4ºC) the carburetor and/or crankcase breather system may begin
to freeze. To prevent icing take the following steps:
1. Replace any old fuel with clean, fresh fuel.
2. Use synthetic 5W-30 or SAE 5W-30 engine oil. Check oil daily or after every 8 hours of use.
3. Turn fuel valve to the open position.
4. Ensure generator is serviced according to the maintenance schedule under “Maintenance” section of manual.
5. Shelter unit from elements.
OPERATION
23
Fig 18
•
•
•
of run time.
•
When the displays P50, it is reminding you to clean the air filter.Run/Maintenance Timer
•
When the displays P100, it is reminding you to change/clean the air filter, clean the air fiter,Run/Maintenance Timer
and change the oil.
To Balance the Load
To obtain the best output and performance of your Ford Generator it is best to make every effort to balance the load on the
outlets. Attempt to spread the load as evenly as possible by utilizing all outlets and try to run higher wattage device on
separate outlets when possible. For example; if you have a device that draws 2,500W and a device that draws 2,000W, put
one plug in the left duplex receptacle and then plug the other device in the right duplex receptacle which would be a more
balance than placing both plugs in a single duplex receptacle putting 4,500W on one receptacle.
ATS function of FG9250E:
Using the ATS function, please follow the instruction manual of ATS box you bought.