The installation environment for the inverter in which this product is being installed is listed Table 3-1-1
Table 3-1-1 Installation Environment.
Item Specifications Remarks
Location Indoors -
Ambient
temperature
-10 to 50°C -
Ambient relative
humidity
5 to 95% -
Environment The place should be away from direct sunlight and free from dust, corrosive gases,
inflammable gases, oil mists, steam, dripping water or vibration. Salty environments
should preferably be avoided. Avoid places where sudden changes in temperature occur
which could cause condensation or freezing.
-
Altitude Up to 1000m -
Please set up so that power terminal may become the lower side.Please set up vertically on a strong building with the
bolt.Please do not turn upside down and do not set up in a horizontal plane.
This option generates heat, and install space more than each of 100 the top and bottom and the right and left to
secure the passage of the cooling style, please.The generated heat is radiated up. Please do not install under a weak
equipment to heat.Moreover, installation respect must use the one of the material that the temperature rise can be
endured enough.
Please consider enough to ventilation so that the ambient temperature of the inverter and the braking resistor should
not exceed the specification value when storing in the control board etc.Please do not store in a small sealing up box
where heat radiation is bad.
WARNING
The surface temperature of resistance becomes 400 or less by the use state.
There is risk of fire or burn.
Please install in a nonflammable thing such as the metals.
There is risk of fire.
Please do not arrange the combustible in surroundings.
There is risk of fire.
3-2 Installation method
3-1 Installation Environment
3 Installation
4
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fuji Electric DB C Series and is the answer not in the manual?

Fuji Electric DB C Series Specifications

General IconGeneral
BrandFuji Electric
ModelDB C Series
CategoryIndustrial Electrical
LanguageEnglish