CAUTION
•Check the wiring again before operating the inverter. Improper wiring may cause unexpected inverter operation or
device operation. There is a risk of accident or injury.
• Since noise is generated by the inverter, motor, and wiring, carefully monitor surrounding sensors
and devices for abnormal operation. There is a risk of accident.
Applicable Table 3-3-1
Model Use electric wire size
DB0.75-2C 2mm
2
DB2.2-2C/DB3.7-2C 2mm
2
DB5.5-2C/DB7.5-2C 3.5mm
2
DB11-2C~DB22-2C
5.5mm
2
DB0.75-4C 2mm
2
DB2.2-4C~DB22-4C
2mm
2
Note 1:The size of the use electric wire is based on 600V vinyl electric wire.(Please use heatproof 75℃ or more.)
Note 2:The wiring length is assumed to be 5m or less.
Recommended connection method
Terminal for braking resistor connection Table 3-3-2
Type Terminal form Connection method
DB0.75-2C
DB0.75-4C
0.75mm
2
Electric wire
(CFGE)
The wiring for 500mm is attached.
Please connect the terminal with wiring.
DB2.2-2C/DB3.7-2C
DB2.2-4C/DB3.7-4C
Connected bar
Board thickness2mm
Φ4.3mm Installation hole
Please connect wiring in connected bar with the bolt
and the nut.
DB5.5-2C/DB7.5-2C
DB5.5-4C/DB7.5-4C
DB11-2C~DB22-2C
DB11-4C~DB22-4C
Connected bar
Board thickness2mm
Φ6mm Installation hole
Earth terminal Table 3-3-3
Type Terminal form Connection method
All models
M4 Terminal
(With screw)
Please connect wiring with the earth terminal.