En-5
(2) Install the air cleaning lter set (set of 2).
1) Set the air cleaning lter into the air cleaning lter frame.
$LUFOHDQLQ
J
¿OWHU
$LUFOHDQLQJ
¿
OWHU
I
UDPH
Air cleaning lter
Air cleaning lter frame
2) Engage the latch at both ends of the lter with the two hooks at the
rear of the air cleaning lter frame.
Hook
(
2 places at the rear
)
Latch (2 places)
Hook (2 places at the rear)
Latch (2 places)
Take care that the air cleaning lter does not project beyond the frame.
3) Engage the six xing locations at the top and bottom of the air
cleaning lter frame with the hooks of the air lter.
5HDURIWKH¿OWHU
)L[LQJORFDWLRQ
KRRNSODFHV
Rear of the lter
Fixing location,
hook (6 places)
(3) Install the two air lters and close the intake grille.
When air cleaning lters are used, the effect will increased by setting
the fan speed to “HIGH”.
Replacing dirty air cleaning lters
Replace lters with the following components (purchased separately).
APPLE-CATECHIN FILTER: UTR-FA13-1
ION DEODORIZATION FILTER: UTR-FA13-2
(1) Open the intake grille and remove the air lters.
(2) Replace them by two new air cleaning lters.
1) Remove the old air cleaning lters in reverse order of their installa-
tion.
2) Install in the same way as for installation of the air cleaning lter
set.
(3) Install the two air lters and close the intake grille.
In regard to the air cleaning lters
APPLE-CATECHIN FILTER (1 sheet)
The lters are disposable lters. (They cannot be washed and reused.)
For storage of the lters, use the lters as soon as possible after the
package has been opened.
(The air cleaning effect decreases when the lters are left in the
opened package)
Generally, the lters should be exchanged about every 3 months.
Please buy dedicated APPLE-CATECHIN FILTER (UTR-FA13-1) (Sold
separately) to exchange the used dirty air cleaning lters.
ION DEODORIZATION FILTER (1 sheet) - light blue
The lters should be exchanged about every 3 years so as to maintain
the deodorizing effect.
Please buy dedicated ION DEODORIZATION FILTER (UTR-FA13-2)
(Sold separately) when exchanging the lters.
Maintenance of ION DEODORIZATION FILTER
In order to maintain the deodorizing effect, please clean the lter in the
following way every 3 months.
(1) Remove the lter.
(2) Clean with water and dry in the air.
1) Flush the lters with high-pressure hot water until the surface of
the lters are covered with water. Please ush with diluent neutral
detergent. (Never wash by reaming or rubbing, otherwise it will
damage the deodorizing effect.)
2) Rinse with water ow.
3) Dry in shade.
(3) Reinstall the lter.
Cleaning body
Wash the body with warm water, and then dry with a clean and soft cloth.
When not using for an extended period
Leave the breaker on for at least 12 hours before starting operation when
it is to be used again.
After extended non-use of the unit
If you have shut down the indoor unit for 1 month or more, perform the
FAN operation for half a day to dry the internal parts thoroughly before
you perform normal operation.
Additional inspection
After long period of use, accumulated dust inside the indoor unit may re-
duce the product performance even if you have maintained the unit with
instructed daily care or cleaning procedures written in this manual.
In such a case, a product inspection is recommended.
For more information, consult authorized service personnel.
TROUBLESHOOTING
The following conditions are not breakdowns or op-
eration failures.
Does not operate immediately:
If the unit is stopped and then immediately started again, the com-
pressor will not operate for about 3 minutes, in order to prevent fuse
blowouts.
Whenever the electrical breaker is turned off then on again, the protec-
tion circuit will operate for about 3 minutes, preventing unit operation
during that period.
Air ow is weak or stops:
When Heating operation is started, indoor unit’s fan may temporarily
stop, to allow internal parts to warm up.
During Heating operation, if the room temperature rises above the
thermostat setting, the outdoor unit will stop, and the indoor unit’s fan
will stop. If you wish to warm the room further, set the thermostat for a
higher setting.
During oil recovery operation, the air ow may stop for approximately
10 minutes. (See page 3)
During Heating operation, the unit will temporarily stop operation (be-
tween 4 and 15 minutes) as the Automatic Defrosting mode operates.
(See page 3)
The fan may operate at low speed during Dry operation or when the
unit is monitoring the room’s temperature.
In the monitor AUTO operation, the fan will operate at low speed.
Flashing lamps:
The OPERATION indicator lamp (green) ashes:
An oil recovery operation is being performed. (See page 3)
The OPERATION indicator lamp (green) ashes:
An automatic defrosting operation is being performed. (See page 3)
9377772411-01.indb 59377772411-01.indb 5 8/30/2019 10:19:43 AM8/30/2019 10:19:43 AM

Other manuals for Fujitsu AIRSTAGE ASUA30TLAV2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu AIRSTAGE ASUA30TLAV2 and is the answer not in the manual?

Fujitsu AIRSTAGE ASUA30TLAV2 Specifications

General IconGeneral
BrandFujitsu
ModelAIRSTAGE ASUA30TLAV2
CategoryAir Conditioner
LanguageEnglish

Related product manuals