1-5. Rotation number of compressor limitation by outdoor
temperature
The minimum rotation number of compressor is limited by outdoor temperature as below.
Cooling/Dry mode
F zone
18°C
E zone
12°C
D zone
7°C
C zone
B zone
A zone
-3°C
-8°C
G zone
22°C
H zone
38°C
Unit: rps
Model name Outdoor temperature zone
Limitation of compressor
rotation number
AOHG14KBTA2
A zone 40
B zone 25
C zone 25
D zone 19
E zone 19
F zone 19
G zone 18
H zone 23
AOHG18KBTA2
A zone 30
B zone 30
C zone 23
D zone 18
E zone 13
F zone 11
G zone 11
H zone 25