EasyManuals Logo
Home>Fujitsu>Air Conditioner>ARXG14KSLAP

Fujitsu ARXG14KSLAP User Manual

Fujitsu ARXG14KSLAP
403 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #285 background imageLoading...
Page #285 background image
1-4. Rotation number of compressor at normal start-up
¢ Model: AOHG14KBTA2
Rotation number of compressor soon after starting is controlled as below.
Rotation number I
Rotation number II
Rotation number III
Rotation number IV
Rotation number V
Rotation number VI
Rotation number VII
Time 1
Time 2 Time 3
Time 4
Time 5
Time 6
Time 7
Rotation number (rps)
I II III IV V VI VII
45 56 68 77 84 93 103
Time (sec)
1 2 3 4 5 6 7
60 140 170 220 280 360 430
¢ Model: AOHG18KBTA2
Rotation number of compressor soon after starting is controlled as below.
Rotation number I
Rotation number II
Rotation number III
Rotation number IV
Rotation number V
Time 1
Time 2 Time 3
Time 4
Time 5
Rotation number
(rps)
I II III IV V
40 56 77 90 99
Time (sec)
1 2 3 4 5
60 240 280 360 400
1-4. Rotation number of compressor at normal start-up - (04-23) - 1. Rotation number control of compressor
CONTROL AND
FUNCTIONS
CONTROL AND
FUNCTIONS

Table of Contents

Other manuals for Fujitsu ARXG14KSLAP

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu ARXG14KSLAP and is the answer not in the manual?

Fujitsu ARXG14KSLAP Specifications

General IconGeneral
BrandFujitsu
ModelARXG14KSLAP
CategoryAir Conditioner
LanguageEnglish

Related product manuals