SAFETY PRECAUTIONS
Do not attempt to install this air conditioner by yourself.
This unit contains no user-serviceable parts. Always consult authorized service person-
nel for repairs.
When moving, consult authorized service personnel for disconnection and installation
of the unit.
Do not become over-exposed to cold air by staying in the direct path of the air ow of
the air conditioner for extended periods of time.
Do not insert ngers or objects into the outlet port or intake grilles.
Do not start and stop air conditioner operation by turning off the electrical breaker and
so on.
In the event of a malfunction (burning smell, etc.), immediately stop operation, turn off
the electrical breaker, and consult authorized service personnel.
Provide occasional ventilation during use.
Do not direct air ow at replaces or heating apparatus.
Do not climb on, or place objects on, the air conditioner.
Do not hang objects from the indoor unit.
Do not set ower vases or water containers on top of air conditioners.
Do not expose the air conditioner directly to water.
Do not operate the air conditioner with wet hands.
Do not touch the switches with sharp objects.
Turn off power source when not using the unit for extended periods.
Always turn off the electrical breaker whenever cleaning the air conditioner or changing
the air lter.
Connection valves become hot during Heating; handle with care.
Check the condition of the installation stand for damage.
Do not place animals or plants in the direct path of the air ow.
When restarting after a long period of disuse in the winter, turn the power switch on at
least 12 hours before starting the unit.
Do not drink the water drained from the air conditioner.
Do not use in applications involving the storage of foods, plants or animals, precision
equipment, or art works.
Do not apply any heavy pressure to radiator ns.
Operate only with air lters installed.
Do not block or cover the intake grille and outlet port.
Ensure that any electronic equipment is at least one metre away from either the indoor
or outdoor units.
Avoid installing the air conditioner near a replace or other heating apparatus.
When installing the indoor and outdoor units, take precautions to prevent access by
infants.
Do not use in ammable gases near the air conditioner.
Before using the appliance, read these “SAFETY PRECAUTIONS” thoroughly and operate in the correct way.
The instructions in this section all relate to safety; be sure to maintain safe operating conditions.
“DANGER”, “WARNING” and “CAUTION” have the following meanings in these instructions:
DANGER
This mark indicates procedures which, if improperly performed, are most likely to
result in the death of or serious injury to the user or service personnel.
WARNING
This mark indicates procedures which, if improperly performed, might lead to the
death or serious injury of the user.
CAUTION
This mark indicates procedures which, if improperly performed, might possibly result
in personal harm to the user, or damage to property.
DANGER
CAUTION
CONTENTS
SAFETY PRECAUTIONS ........................................ 2
FEATURES AND FUNCTIONS ............................... 3
PREPARATORY OPERATION ................................ 5
OPERATION ............................................................ 6
TIMER FUNCTIONS ............................................... 8
ON/OFF TIMER ....................................................... 8
WEEKLY TIMER ...................................................... 9
TEMPERATURE SET BACK TIMER ......................11
ECONOMY OPERATION ...................................... 12
CLEANING AND CARE ......................................... 12
TROUBLESHOOTING .......................................... 13
OPERATING TIPS ................................................. 15
SELF-DIAGNOSIS ................................................ 17
9374379569-02_OM.indb Sec1:29374379569-02_OM.indb Sec1:2 2012-3-27 16:49:452012-3-27 16:49:45

Other manuals for Fujitsu ARYG24LMLA

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu ARYG24LMLA and is the answer not in the manual?

Fujitsu ARYG24LMLA Specifications

General IconGeneral
TypeAir conditioner indoor unit
Multi-split-
Product colorBlack, Stainless steel
Inverter technologyYes
Refrigerating mediumR410A
Air conditioner functionsCooling, Dehumidifying, Heating
Refrigerating medium weight1700 g
Cooling capacity in watts (nominal)- W
AC input voltage230 V
AC input frequency50 Hz
Hourly energy consumption (cooling)- kWh
Design load (heating) (Warmer heating season)- kW
Energy efficiency class (heating) (Average heating season)A+
Outdoor unit noise level- dB
Airflow1100 m³/h
Indoor unit typeCassette
Indoor unit depth700 mm
Indoor unit width1135 mm
Indoor unit noise level (high speed)31 dB