EasyManuals Logo
Home>Fujitsu>Air Conditioner>ASY17RS

Fujitsu ASY17RS User Manual

Fujitsu ASY17RS
19 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #7 background imageLoading...
Page #7 background image
En-6
OPERATION
Room Temperature
30 °C or more Cooling 27 °C
27 °C to 30 °C Cooling 26 °C
25 °C to 27 °C Dry 24 °C
23 °C to 25 °C Dry 22 °C
Less than 23 °C Dry 20 °C
Temperature
Setting
(normal setting)
Operating
Mode
About AUTO CHANGEOVER Operation [REVERSE CYCLE MODEL]
When AUTO CHANGEOVER operation is selected, the air
conditioner selects the appropriate operation mode (Cool-
ing or Heating) in response to your rooms temperature.
When AUTO CHANGEOVER operation first selected, the
fan will operate at very low speed for about one minute,
during which time the unit detects the room conditions
and selects the proper operating mode.
When the air conditioner has adjusted your rooms tem-
perature to near the thermostat setting, it will begin moni-
tor operation. In the monitor operation mode, the fan will
To Set the Thermostat
Press the TEMPERATURE set button.
COOLING MODEL
When set to When set to When set to When set to When set to
2K (2 °C) lower 1K (1 °C) lower normal 1K (1 °C) higher 2K (2 °C) higher
REVERSE CYCLE MODEL
The temperature can be set to 27°, 25°, 23°, 21° or 19° (C).
About three seconds later, the entire display will reappear.
The thermostat setting should be con-
sidered a standard value, and may dif-
fer somewhat from the actual room tem-
perature.
Example: When set to normal
operate at low speed. If the room temperature subse-
quently changes, the air conditioner will once again se-
lect the appropriate operation (Heating, Cooling) to ad-
just the temperature to the value set in the thermostat.
(The monitor operation range is ±2 °C relative to the ther-
mostat setting.)
If the mode automatically selected by the unit is not what
you wish, see page 7 and select one of the mode opera-
tion (HEAT, COOL, DRY, FAN).
To Select AUTOMATIC Operation
1
Press the START/STOP button (Fig. 5 M).
The air conditioner will start operation.
2
Press the MASTER CONTROL button to select AUTO
(Fig. 5 H).
The operating mode AUTO will appear alone in the display. The trans-
mit indicator will flash to indicate the command has been sent, and about
three seconds later the entire display panel will reappear.
Instructions relating to heating (*) are applicable only to HEAT & COOL MODEL (Reverse Cycle).
About Automatic Operation [COOLING MODEL]
Depending on the room temperature at the time opera-
tion begins, the operating mode will be switched auto-
matically as shown in the accompanying table. Also, de-
pending on the operating mode, the room temperature
setting will cause the normal temperature to be set as
shown.
Once the operating mode has been set, the mode will not
change even if the room temperature changes.
In the dry mode, the fan will operate slowly to prevent
room humidity from rising, and the room fan may stop.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu ASY17RS and is the answer not in the manual?

Fujitsu ASY17RS Specifications

General IconGeneral
BrandFujitsu
ModelASY17RS
CategoryAir Conditioner
LanguageEnglish

Related product manuals