3. Fan control
Tr: Room temperature
Ts: Setting temperature
3-1. Indoor fan control
¢ Compact cassette type
Fan speed
Indoor fan speed is defined as below.
Operation mode Fan mode
Speed (rpm)
AUXG07KVLA AUXG09KVLA AUXG12KVLA AUXG14KVLA
Heating
HIGH 590 590 650 830
MED+ 570 570 620 770
MED 540 540 580 730
LOW 490 490 520 630
QUIET 440 440 460 500
Cool air
prevention
400 400 400 400
S-LOW 300 300 300 300
Cooling/Fan
HIGH 590 590 650 730
MED 540 540 580 630
LOW 490 490 520 540
QUIET 440 440 460 460
Soft quiet
400*
1
400*
1
400*
1
400*
1
S-LOW
300*
2
300*
2
300*
2
300*
2
Dry
X zone: 440
J zone: 440
X zone: 440
J zone: 440
X zone: 460
J zone: 460
X zone: 460
J zone: 460
*1: Fan mode only
*2: Cooling mode only
Fan operation
Airflow can be switched in 5 steps such as AUTO, QUIET, LOW, MED, HIGH while indoor unit fan
only runs.
When fan mode is set at AUTO, it operates on MED fan speed.
3-1. Indoor fan control
- (04-28) - 3. Fan control
CONTROL AND
FUNCTIONS
CONTROL AND