11
8. ELECTRICAL WIRING
(1) Match the terminal block numbers
and connection cord colors with
those of the outdoor unit. Erroneous
wiring may cause burning of the
electric parts.
(2) Connect the connection cords firmly
to the terminal block. Imperfect
installation may cause a fire.
(3) Always fasten the outside covering
of the connection cord with the cord
clamp. (If the insulator is chafed,
electric leakage may occur.)
(4) Always connect the ground wire.
1. INDOOR UNIT SIDE
(1) Remove the electric component box.
(3) Remove the electric component box cover.
Remove the three tapping screws.
Be careful not to pinch the lead wires
between the electric component box and
base.
Fig. 33
Electric component box
Do not remove the screws. If the stays
are removed, the electric component box
will fall.
2.
Pull out the electric component box.
Fig. 35
Electric component box
Fig. 34
Electric component box
Remove the four
tapping screws.
Fig. 36
Electric component box cover
Base

Other manuals for Fujitsu SPLIT TYPE AIR CONDITIONER

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu SPLIT TYPE AIR CONDITIONER and is the answer not in the manual?

Fujitsu SPLIT TYPE AIR CONDITIONER Specifications

General IconGeneral
BrandFujitsu
ModelSPLIT TYPE AIR CONDITIONER
CategoryAir Conditioner
LanguageEnglish

Related product manuals