Performance Data Sheet
Hodel: GE RPWF
Use Replacement Cartridge RPWR
Theconcentration of the indicated substances in water entering the system was reduced to a concentration lessthan or equal tothe permissible
limit for water leaving the system as specified in NSF/ANStStandard/42 and Standard 53.System tested and certified by NSFInternational against
NSF/ANSIStandard/42 and Standard 53 for the reduction of substances listed below.
Capacity 170 Gallons (643.5 Liters). Contaminant Reduction Determined )y NSF testing.
AverageProduct
NSFSpecified AvgYo V_oter
for Reduction AverageInfluent ChallengeConcentration Reduction Concentration
2.0 mg/L
7,655,555 pts/mL
109 MFL
0.009 mg!L
0.016 mg!L
0.08 mg/L
10£750 cysts/L
0.140 mg/L
0.158 mg/L
0.006 mg/L
0.006 mg!L
0.002 mg/L
0.222 mg/L
0.015 mg!L
0.218 mg!L
0.278 mg/L
*Based on the useof Cryptosporidium parvum oocysts.
2.0 mg/L _+10%
At least 10,000 particles/mL
107 to 108 fibers/L; fibers
greater than lOtJm in length
0.009 mg/L _+10%
0.015 mg/L _+10%
0.08 mg!L _+10%
Minimum 50,000 cysts/L
0.15 mg!L _+10%
0.15 mg/L _+10%
0.006 mg/L _+10%
0.006 mg/L _+10%
0.002 mg/L _+10%
0.225 mg/L _+10%
0.015 mg/L _+10%
0.210 mg/L_+lO%
0.500 mg/L _+10%
97.4% 0.05 mg/L
99.0% 71,850 pts/ml
99.99% <1 MFL
94.4% 0.0005 mg/L
96.4% 0.001 mg/L
98.8% 0.001 mg/L
99.99% 3 cyst!L
99.3% 0.001 mg/L
98.3% 0.002 mg/L
91% 0.0003 mg/L
88.3%% 0.0007 mg/L
99% 0.00002 mg/L
99.8% 0.0005 mg/L
93.5% 0.001 mg/L
99.9% 0.0001
97.7% 0.0015 mg/L
Max Permissible
Productwater
Concentration
N/A
N/A
N/A
0.003 mg!L
0.005 mg!L
0.04 mg/L
N/A
0.010 mg!L
0.010 mg/L
0.002 mg/L
0.002 mg/L
0.0002 mg/L
0.075 mg!L
0.003 mg/L
0.07 _!L
N/A
Requirements
>50%
>85%
->99%
N/A
N/A
N/A
->99.95%
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
->95%
The following pharmaceutical reduction claims have not been certified by NSF International. Claims tested and verified
by independent laboratory:
' I , Ha×Permissible
Contaminant ' ' NSFspecified
Reduction Average Influent ChallengeConcentration
1088 ng/L N/A
845 ng!I N/A
898 ng/L N/A
945 ng/L N/A
403 ng!L N/A
Test Report
J-00102044
J-00106249
J-00102069
J-00102058
J-00102065
J-00102059
J-00102057
J-00102052
J-00102053
J-00102054
J-00104087
J-00102063
J-00102067
J-00102061
J-00102064
J-00102070
Avg% Average Product Water i _ ProductWoter NSF
Redu_ion ...... Concentration ' Concentration Test Repo_
99.5% 5.0 ng/L N/A J-00103221
99.4% 5.0 ng/L N/A J-00103221
98.8% 9.9 ng/L N/A J-00103726
99.4% 5.5 ng/L N/A J-00103727
99.5% 2.0 ng/L N/A J-00103221
Application Guidelines/Water Supply Parameters
Service Flow Water Pressure 172- 827 kPa)
Water Su_ Water Temperature 'i53° F- 100° F _:6_ _ C)
It isessentialthat the manufacturer'srecommendedinstallation,maintenanceand filter replacementrequirementsbecarriedout for the product to performas advertised.
SeeInstallation Hanualfor Warranty information.
Note: While the testing was performed under standard laboratory conditions,
actual performance may vary.
Replacement Cartridge: RPWEForestimated costs of replacement elements
please call 1-800-626-2002 or visitour website at www.geapplianceparts.com.
L_WARNING
Toreduce the risk associated with ingestion of contaminants:
. Do not use with water that is microbiologically unsafe or of unknown quality
without adequate disinfection before and after the system. Systems certified
for cyst reduction may be usedon disinfected water that may contain filterable
cysts. EPAEstablishment Number 070595-MEX-O01.
NOTICE
To reduce the risk associated with property damage due to water leakage:
, Read and follow use instructions before installation and use of this system.
, Installation and use MUST comply with all state and local plumbing codes.
, Do not install if water pressure exceeds 120 psi (827 kPa). If your water pressure
exceeds 80 psi,you must install apressure-limiting valve.Contact a plumbing
professional if you are uncertain how to check your water pressure.
, Donot installwhere water hammer conditions may occur. Ifwater hammer
conditions exist you must install a water hammer arrester. Contact a plumbing
professional if you are uncertain how to checkfor this condition.
, Donot installon hot water supply lines The maximum operating water
temperature ofthis filter system is100° F(38°C).
. Protect filter from freezing. Drainfilter when temperatures drop
below 33°F10.6°C).
, Thedisposable filter cartridge must be replaced every 6months at the
rated capacity, or sooner if a noticeable reduction in flow rate occurs.
For conditions of use, health claims certified by the California Department of Public
Health, and replacements, see performance data sheet. California Department
of Public Health Certification #11-2110. The contaminants or other substances
removed or reduced by this water filter are not necessarily in all users' water.
GE
Appliances
Appliance Park
Louisville, KY 80225
geapplianceparts.com
45
System tested and ce@fied by NSF
Internation@ against NSF/ANSI Standard I
42 and Standard 53inmodeIGE RPWF I
for the reduction of the claims specified
on the performance data sheet.
34-8708-7119-0
EPA #070595-MEX-001
© 2012 General Electric Company PC71879

Other manuals for GE cafe

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GE cafe and is the answer not in the manual?

GE cafe Specifications

General IconGeneral
BrandGE
Modelcafe
CategoryRanges
LanguageEnglish

Related product manuals