35 36
7 Technical Parameters & Block Diagram
7.1 Technical Parameters
GEP12-L-10
15600
800
200~650
180
370
180~800
0
26/26/26
33/33/33
3
2/2/2
12000
12000
12000
220, 3L/N/PE or 3L/PE
50/60
31.5
<3%
60
160
109
98%
97.7%
GEP15-L-10
19500
800
200~650
180
370
180~800
0
26/26/26
33/33/33
3
2/2/2
15000
15000
15000
220, 3L/N/PE or 3L/PE
50/60
40
~1 (Adjustable from 0.8 leading to 0.8 lagging)
<3%
60
160
109
98%
97.7%
Integrated
Integrated
Integrated
Optional
Type II
Type II
Integrated
Integrated
Integrated
Integrated
Class I
C
-30~60
0~100%
≤3000
Fan Cooling
LCD & LED or APP & LED
RS485, WiFi, USB, PLC (Optional)
40
480*590*200
IP65
<1
Transformerless
VDE0126-1-1/VDE-AR-N 4105
IEC62109-1&2
EN61000-6-1,EN61000-6-2,EN61000-6-3,EN61000-6-4
GEP20-L-10
26000
800
200~650
180
370
180~800
0
26/26/26
33/33/33
3
2/2/2
20700
20700
20700
220, 3L/N/PE or 3L/PE
50/60
54.5
<3%
60
160
109
98%
97.7%
Technical Data
PV String Input Data
Max. DC Input Power (W)
Max. DC Input Voltage (V)
MPPT Range (V)
Start-up Voltage (V)
Nominal DC Input Voltage (V)
PV Input Operating Voltage range(V)
Max. Inverter Backfeed Current To The array (A)
Max. Input Current (A)
Max. Short Current (A)
No. of MPP Trackers
No. of Input Strings per Tracker
AC Output Data
Nominal Output Power (W)
Max. Output Power (W)
Max. Output Apparent Power (VA) [1]
Nominal Output Voltage (V)
Nominal Output Frequency (Hz)
Max. Output Current (A)
Output Power Factor
Output THDi (@Nominal Output)
Current(inrush)
Maximum Output Fault Current
Maximum Output Over Current Protection (A)
Efficiency
Max. Efficiency
Europen Efficiency
Protection
Anti-islanding Protection
Input Reverse Polarity Protection
PV String Current Monitoring
Anti-PID Function for Module
DC Surge Protection
AC Surge Protection
Residual Current Monitoring Unit
Output Over Current Protection
Output Short Protection
Output Over Voltage Protection
Protective Class
Decisive Voltage Classification(DVC)
General Data
Operating Temperature Range (℃)
Relative Humidity
Operating Altitude (m)
Cooling
User Interface
Communication
Weight (kg)
Size (Width*Height*Depth mm)
Protection Degree
Night Self Consumption (W)
Topology
Certifications & Standards
Grid Regulation
Safety Regulation
EMC
*1:For Brazil Max. Output Power GEP25-10 is 25000W.
*2:For Brazil Max. Output Apparent Power GEP25-10 is 25000W.
*3:For Brazil Nominal Output Voltage GEP25-10 is 380V, GEP36-10 is 380V.
*4:For Brazil Communication GEP25-10 is RS485, WiFi, USB, PLC (Optional); GEP36-10 is RS485, WiFi,USB, PLC (Optional).
Integrated
Integrated
Integrated
Optional
Type II
Type II
Integrated
Integrated
Integrated
Integrated
Class I
C
-30~60
0~100%
≤3000
Fan Cooling
RS485, WiFi, USB, PLC (Optional)*4
LCD & LED or APP & LED
40
480*590*200
IP65
<1
Transformerless
IEC62109-1&2
EN61000-6-1,EN61000-6-2,EN61000-6-3,EN61000-6-4
Technical Data
PV String Input Data
Max. DC Input Power (W)
Max. DC Input Voltage (V)
MPPT Range (V)
Start-up Voltage (V)
Nominal DC Input Voltage (V)
PV Input Operating Voltage range(V)
Max. Inverter Backfeed Current To The array (A)
Max. Input Current (A)
Max. Short Current (A)
No. of MPP Trackers
No. of Input Strings per Tracker
AC Output Data
Nominal Output Power (W)
Max. Output Power (W)
Max. Output Apparent Power (VA) [1]
Nominal Output Voltage (V)
Nominal Output Frequency (Hz)
Max. Output Current (A)
Output Power Factor
Output THDi (@Nominal Output)
Current(inrush)
Maximum Output Fault Current
Maximum Output Over Current Protection (A)
Efficiency
Max. Efficiency
Europen Efficiency
Protection
Anti-islanding Protection
Input Reverse Polarity Protection
PV String Current Monitoring
Anti-PID Function for Module
DC Surge Protection
AC Surge Protection
Residual Current Monitoring Unit
Output Over Current Protection
Output Short Protection
Output Over Voltage Protection
Protective Class
Decisive Voltage Classification(DVC)
General Data
Operating Temperature Range (℃)
Relative Humidity
Operating Altitude (m)
Cooling
User Interface
Communication
Weight (kg)
Size (Width*Height*Depth mm)
Protection Degree
Night Self Consumption (W)
Topology
Certifications & Standards
Grid Regulation
Safety Regulation
EMC
~1 (Adjustable from 0.8 leading to 0.8 lagging)
GEP25-10
32500
1100
200~950
180
600
180~1100
0
26/26/26
33/33/33
3
2/2/2
25000
27500
*1
27500
*2
400
*3
, 3L/N/PE or 3L/PE
50/60
40
<3%
60
160
109
98.3%
98%
IEC61727, IEC62116
GEP36-10
46800
1100
200~950
180
600
180~1100
0
26/26/26
33/33/33
3
2/2/2
36000
36000
36000
400
*3
, 3L/N/PE or 3L/PE
50/60
53.3
<3%
60
160
109
98.3%
98%
IEC61727、IEC62116
GEP29.9-10
45000
1100
200~950
180
600
180~1100
0
26/26/26
33/33/33
3
2/2/2
29900
29900
29900
400, 3L/N/PE or 3L/PE
50/60
43.3
<3%
60
160
109
98.3%
98%
AS4777.2