5
Specifications
SPECIFICATIONS
9-1/4"
12-1/2" 3-5/8"
9-3/4"
2"
10-1/2"
14"
9" dia.
14”
9” dia.
Reverse Osmosis System
Model GXRV40TBN
Supply water pressure limits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40-100 psi (280-689 kPa)
Supply water temperature limits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40-100 °F (4-38 °C)
Maximum total dissolved solids (TDS) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2000 ppm
Maximum water hardness @ 6.9 pH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 gpg
Maximum iron, manganese, hydrogen sulfide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0
Chlorine in water supply (max. ppm) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.0
Supply water pH limits (pH) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-10
Product (quality) water, 24 hours
1
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14.76 gal. (55.9 liters)
Percent rejection of TDS, minimum (new membrane)
1
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86.5
Automatic shutoff control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . yes
Efficiency
2
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10.6 %
Recovery
3
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21.2 %
Rated Service Flow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.8 gpm (3.0 lpm)
This system conforms to NSF/ANSI 58 for VOC reduction. See performance data sheet for individual contaminants and
reduction claims.
1
@ Feed water supply at 50 psi, 77°F, and 750 TDS. Quality water production, amount of waste water and percent rejection all
vary with changes in pressure, temperature and total dissolved solids.
2
Efficiency rating means the percentage of the influent water to the system that is available to the user as reverse osmosis
treated water under operating conditions that approximate typical daily usage.
3
Recovery rating means the percentage of the influent water to the membrane portion of the system that is available to the user
as reverse osmosis treated water when the system is operated without a storage tank or when the storage tank is bypassed.
Visually Contaminated Water Sources: Do not use for the treatment of water that is visually contaminated (cloudy) or has an
obvious contamination source, such as contamination by raw sewage.
Non-potable Water Sources: Do not attempt to use this product to make safe drinking water from non-potable water sources.
Do not use the system on microbiologically unsafe water, or water of unknown quality without an adequate disinfection before or
after the system. This system is certified for cyst reduction and may be used on disinfected water that may contain filterable cysts.
Arsenic Reduction: This system shall only be used for arsenic reduction on chlorinated water supplies containing detectable
residual free chlorine at the system inlet. Water systems using an inline chlorinator should provide a one minute chlorine contact
time before the reverse osmosis system.
Nitrate/Nitrite Test Kit: This system is supplied with a nitrate/nitrite test kit. Product water should be monitored periodically
according to the instructions provided with the test kit.
Installations In the Commonwealth of Massachusetts: The Commonwealth of Massachusetts requires installation be
performed by a licensed plumber and do not permit the use of saddle valves. Plumbing code 248-CMR of the Commonwealth of
Massachusetts must be followed in these cases.
Product Water Testing: The Reverse Osmosis system contains a replaceable treatment component critical for the effective
reduction of total dissolved solids. Product water should be tested periodically to verify that the system is performing properly.
Replacement of the reverse osmosis component: This reverse osmosis system contains a replaceable component critical to
the efficiency of the system. Replacement of the reverse osmosis component should be with one of identical specifications, as
defined by the manufacturer, to assure the same efficiency and contaminant performance.
Dimensions:
RO Product
Water FaucetStorage Tank Reverse Osmosis Assembly
9-1/4”
12-1/2”
3-5/8”
9-3/4”
10-1/2”
Remineralization/
Antimicrobial Filter
2”

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GE GXRV40TBN and is the answer not in the manual?

GE GXRV40TBN Specifications

General IconGeneral
BrandGE
ModelGXRV40TBN
CategoryWater Filtration Systems
LanguageEnglish

Related product manuals