Specifications
SPECIFICATIONS: Performance Data
Performance Data for Reverse Osmosis Water Filtration System GXRV40TBN
M
odel
Replacement
Elements
Operating
Pressure Range
Operating Temp -
erature Range
Recovery
Rating
Efficiency
Rating
Daily Production
Rate (DPR)
GXRV40TBN
FQ18MN,
FQ18PN,
FQ18RT
40 -100 PSI
(
275 - 689 kPa)
40 - 100 °F
(
5 - 38 °C)
21.18% 10.63%
14.76 gal./day
(
55.9 liters/day)
Manufactured by: GE Appliances
Louisville, KY 40225
800.952.5039 (US)
* Tested and verified by IAPMO.
** Tested by Spectrum Labs, a qualified independent laboratory, against accepted industry protocol.
NSF/ANSI Standard 42 Minimum Reduction Overall % Reduction Results
Chlorine Taste & Odor <0.5 mg/L 97.5% Pass
NSF/ANSI Standard 53*
Influent Challenge
Concentration
Maximum Permissible
Concentration
Overall %
Reduction
Results
VOC Surrogate Test 300 μg/L 15 μg/L 99.8% Pass
MTBE 15 μg/L 5 μg/L 97.8% Pass
Perfluorooctanoic acid (PFOA) &
Perfluorooctane sulfonate (PFOS)
1.5 μg/L ±10% 0.07 μg/L 97.4% Pass
NSF/ANSI Standard 58
Influent Challenge
Concentration
Maximum Permissible
Concentration
Overall %
Reduction
Results
Asbestos*
10
7
to 10
8
fibers/L
99% reduction >99.9% Pass
Arsenic (pentavalent) 0.30 mg/L ±10% 0.010 mg/L 98.2% Pass
Barium 10 mg/L ±10% 2.0 mg/L 97.8% Pass
Cadmium 0.03 mg/L ±10% 0.005 mg/L 98.1% Pass
Chromium (VI) 0.3 mg/L ±10% 0.1 mg/L 97.0% Pass
Chromium (III) 0.3 mg/L ±10% 0.1 mg/L 98.3% Pass
Copper 3.0 mg/L ±10% 1.3 mg/L 98.8% Pass
Cysts ≥50,000 particles/mL 99.95% 99.99% Pass
Lead 0.15 mg/L ±10% 0.010 mg/L 99.1% Pass
Fluoride 8.0 mg/L ±10% 1.5 mg/L 96.5% Pass
Nitrate plus Nitrite (as N) 30 mg/L ±10% 10.0 mg/L 75.4% Pass
Nitrate (as N) 27.0 mg/L ±10% 10.0 mg/L 74.9% Pass
Nitrite (as N) 3.0 mg/L ±10% 1.0 mg/L 80.9% Pass
Radium 226/228 25 pCi/L ±10% 5 pCi/L 80% Pass
Selenium 0.10 mg/L ±10% 0.05 mg/L 98.0% Pass
Turbidity 11 ±1 NTU 0.5 NTU 99.0% Pass
TDS 750 mg/L ±40 187 mg/L 90.6% Pass
Ammonium**
1.2 mg/L ±10% 90% Pass
Bicarbonate**
300 mg/L ±10% 96% Pass
Bromide**
1.5 mg/L ±10% 89% Pass
Chloride**
800 mg/L ±10% 92% Pass
Magnesium**
30 mg/L ±10% 97% Pass
Sodium**
350 mg/L ±10% 88% Pass
Sulfate**
800 mg/L ±10% 98% Pass
Tannin**
3.0 mg/L ±10% 97% Pass
Zinc**
15 mg/L ±10% 98% Pass