Installation Instructions
MAKING THE LP CONVERSION
IF SOLD OUTSIDE THE U.S. AND CANADA:
,_tWt'_K|'_ | |'_qtJ : Ifyou wish to use this product
with Liquefied Petroleum (LP)gas containing greater
than 10% butane, you must purchase a butane
conversion kit. To order, please call 1.888.664.8403 or
1.787.276.4051.
Model Butane Kit #
JGP940 WB28T10228
JGPZZ3 &
WB28T10283
PGP943
JGP329 WB28T10234
r_ SAFETY INFORMATION YOU
SHOULD KNOW
The pressure regulator and burner orifices are set
for natural gas. To use LP gas,
the regulator and burner orifices must
be converted. The LP orifice spuds for
the cooktop burners can be located in the literature
package attached to the regulator.
JLL,_L,I/IUi_I: The cooktop, as shipped from
the factory, is set for use with natural gas. If you
wish to use your cooktop with LP gas, you must
first replace the orifices and convert the pressure
regulator.
,AWARN ING: Thisconversion
must be performed by a qualifiedinstaller
or gas supplierinaccordance withthe
manufacturer'sinstructionsand allcodes
and requirementsof the authorityhaving
jurisdiction. Failure to follow instructions could
result in serious injury or property damage. The
qualified agency performing this work assumes
responsibility for the conversion.
,_&L,_!,J|IUI_I: The following adjustments
must be made beforeturning
on the burner.Failuretodo so could resultin
seriousinjury.Be sure pressureregulatorhas been
convertedas describedinStep 2.
TOOLS YOU WILL NEED
FOR LP CONVERSION
Phillips-Head 7mm Nutdriver
Screwdriver
Pliers
Safety Glasses
No.!5 Torx-Head
Driver
Small Flat-Head
Screwdriver (4mm or
5/]2" tip size, 60mm
long)
13
[2]
B]
[]
ADJUST YOUR COOKTOP FOR USE
WITH LP GAS
Disconnect all electrical power, at the main
circuit breaker or fuse box.
Shut off the gas supply to the cooktop
by closing the manual shut-off valve.
Adjust the pressure regulator, by the following
instructions:
* Unscrew the cap.
* Place your thumb against the flat side of the
spring retainer and press down to remove
the retainer.
* Carefully look at the spring retainer to locate
the NAT or LP position.
Cap Gasket
NAT. Position
Position
Pressure Regulator
, Turn the spring retainer over so that LP is
showing on the bottom.
, Snap the retainer back into position.
, Screw the cap back onto the regulator.