Example 8-1: Configuring TACACS+:
ML1200#
show tacplus servers
ID TACACS+ Server Port Encrypt Key
=======================================
1 10.21.1.170 1 Enabled secret
2-- ---- --
3-- ---- --
4-- ---- --
5-- ---- --
ML1200# user
ML1200(user)##
show tacplus status
TACACS+ Status: Disabled
ML1200(user)## tacplus enable
TACACS+ Tunneling is enabled.
ML1200(user)## tacserver add id=2 ip=10.21.1.123 encrypt=enable ke
TACACS+ server is added.
ML1200(user)## show tacplus servers
ID TACACS+ Server Port Encrypt Key
=======================================
1 10.21.1.170 1 Enabled secret
2 10.21.1.123 1 Enabled some
3-- ---- --
4-- ---- --
5-- ---- --
ML1200(user)## tacserver delete id=2
TACACS+ server is deleted.
ML1200(user)## show tacplus servers
ID TACACS+ Server Port Encrypt Key
=======================================
1 10.21.1.170 1 Enabled secret
2-- ---- --
3-- ---- --
4-- ---- --
5-- ---- --
ML1200(user)## tacplus disable
TACACS+ is disabled.
ML1200(user)##