32
NX-4V2 Control
COMMUNICATOR CODES FOR SLOW SPEED FORMATS ONLY
The digit programmed in each of the following locations will be sent as the upper HEX digit in place of the alarm event code.
The zone ID or user ID will always be reported as the lower HEX digit (1-F). For example, if the zone ID or user ID is 6, the 4+2
lower digit will be “6”. (Refer to Appendix 4 on page 41.)
If Segments 2-8 are left as “0” (unprogrammed), they will follow the Segment 1 selection.
If Segment 1 is left as “0” and the feature is enabled, the NX-4V2 will report “”A”.
LOC PG DESCRIPTION DEFAULT PROGRAMMING DATA
56 22 RESTORE COMMUNICATOR CODE 0 _
57 22 BYPASS COMMUNICATOR CODE 0 _
58 22 TAMPER COMMUNICATOR CODE 0 _
59 22 TROUBLE COMMUNICATOR CODE 0 _
60 22
SENSOR LOW BATTERY COMMUNICATOR CODE
0 _
61 22 SENSOR MISSING COMMUNICATOR CODE 0 _
62 22 DURESS 0-0 _ _
63 22 AUXILIARY 1 0-0 _ _
64 22 AUXILIARY 2 0-0 _ _
65 22 KEYPAD PANIC 0-0 _ _
66 22 KEYPAD MULTIPLE CODE ENTRY TAMPER 0-0 _ _
67 22 BOX TAMPER / BOX TAMPER RESTORE 0-0-0-0 _ _ _ _
68 22 AC FAIL / AC RESTORE 0-0-0-0 _ _ _ _
69 22 LOW BATTERY / LOW BATTERY RESTORE 0-0-0-0 _ _ _ _
70 22 POWER SHORT / POWER SHORT RESTORE 0-0-0-0 _ _ _ _
71 22 BELL TAMPER / BELL TAMPER RESTORE 0-0-0-0 _ _ _ _
72 22
TELEPHONE LINE CUT / LINE CUT RESTORE
0-0-0-0 _ _ _ _
73 22 Reserved 0-0-0-0 _ _ _ _
74 23
EXPANDER TROUBLE / EXP TROUBLE RESTORE
0-0-0-0 _ _ _ _
75 23 FAILURE TO COMMUNICATE 0-0 _ _
76 23 LOG FULL COMMUNICATOR CODE 0-0 _ _
77 23 OPENING CODE COMMUNICATOR CODE 0 _
78 23 CLOSING COMMUNICATOR CODE 0 _
79 23 AUTOTEST COMMUNICATOR CODE 0-0 _ _
80 23 RECENT CLOSING AND EXIT ERROR 0-0 _ _
81 23
START PROGRAMMING / END PROGRAMMING
0-0-0-0 _ _ _ _
82 23 END DOWNLOAD 0-0-0-0 X X _ _
83 23 CANCEL COMMUNICATOR CODE 0 _
84-109 23 RESERVED
110 23 ZONE TYPE 1 ALARM EVENT CODE 8 _
111 23 ZONE TYPE 1 CHARACTERISTIC SELECT
Segment 1
1 = Fire (enable for fire zone)
2 = 24-Hour (enable for non-fire 24 hour)
3 = Keyswitch zone
4 = Follower (enable for burg zones that are
instant during non-entry times)
5 = Delay 1 zone (enable to follow Timer 1 Entry/Exit times)
6 = Delay 2 zone (enable to follow Timer 2 Entry / Exit times)
7 = Interior (Enable for auto bypass or stay arming)
8 = Local Only (enable if zone is not to be reported)
Segment 2
1 = Keypad audible on alarm.
2 = Yelping siren on alarm.
3 = Temporal siren on alarm.
4 = Chime.
5 = Bypassable.
6 = Group Shunt.
7 = Force armable.
8 = Entry Guard.
Segment 3
1 = Fast Loop Response.
2 = Double End of Line Tamper zone.
3 = Trouble zone (Day zone).
4 = Cross Zone.
5 = Dialer Delay zone.
6 = Swinger zone.
7 = Restore reporting.
8 = Listen-In.
Segment 4
1 = Zone Activity Monitor.
2 = End of Line Resistor Defeat.
3-8 = Reserved.
Segment 5 RESERVED