16. What to do if…
Problem Solution
Motor does not run. • Motor not plugged in.
Please check the plug connection.
• Check connecting cable for possible
damage.
• Check the mains voltage and allow the
cause of the voltage break down to be
tested by a specialist
electrician.
Instead of in the upwards direction, motor
runs downwards.
• The control leads are interchanged.
Exchange black/brown control leads.
Motor only runs in one
direction.
• Motor in the end position.
Run motor in the opposite direction.
Readjust the end positions, if necessary.
After running several times,
the motor breaks down and
no longer responds.
• The motor became too hot and has
switched off.
Try it again after a cooling time of about
15 min.
The blind is in the upper position,
actuates the limit stop switch and can
no longer be moved downwards.
• The motor was installed upside down or the
lower end position has been overrun and
the lift tapes were wound up incorrectly.
Allow free mobility of the limit stop switch.
Reset the end stops.
17. Maintenance
The drive is maintenance-free.
18. Technical data
Technical data GJ56.. E06 with electronic end stop
GJ5603k GJ5606k GJ5606
1)
GJ5610 GJ5620
Voltage 230 V~/50 Hz
Current 0,40 A 0,40 A 0,40 A 0,60 A 0,85 A
Cos Phi (cosj) > 0,95
Inrush current (factor) x 1,2
Power 90 W 93 W 90 W 135 W 190 W
Torque 3 Nm 6 Nm 6 Nm 10 Nm 2 x 10 Nm
Speed 26 1/min
Protection class IP 54
Limit switch range 200 rotations
Operating mode S2 4 min. S2 4 min. S2 6 min. S2 4 min. S2 4 min.
Length 319,5 mm 319,5 mm 324,5 mm 329,5 mm 356,7 mm
Diameter 55 mm
Weight approx.
1,50 kg
approx.
1,50 kg
approx.
1,60 kg
approx.
1,70 kg
approx.
2,20 kg
Ambient temperature /
humidity
Operation: T = -10°C .. +60°C / H max. 90%
Storage : T = -15°C .. +70°C / dry and non-condensing place
1)
Run-time optimized version
Subject to technical modifications