English 5
Minimum clearances
Sufficient cooling for the amplifier and function-
ing of the reflex port must be ensured if the
loudspeaker is installed in a restricted space
such as a cabinet or integrated into a wall
structure. The surroundings of the loudspeaker
must always be open to the listening room with
a minimum clearance of 5 centimeters (2”)
behind, above and on both sides of the loud-
speaker. The space adjacent to the amplifier
must either be ventilated or sufficiently large to
dissipate heat so that the ambient temperature
does not rise above 35 degrees Celsius (95°F).
Mounting options
The 8030A offers several mounting options: The Iso-
Pod™ (Isolation Positioner/Decoupler™) vibration
insulating table stand allows tilting the loudspeaker
for correct alignment of the acoustic axis. The stand
can be attached to three mounting points allowing
vertical and symmetrical horizontal positioning. On
the base of the loudspeaker is a 3/8” UNC threaded
hole compatible with a standard microphone stand.
On the rear there are two M6x10 mm threaded
holes for Omnimount
®
size 20.5 brackets.
Maintenance
No user serviceable parts are to be found within
the amplifier unit. Any maintenance or repair of the
8030A unit should only be undertaken by qualified
service personnel.
Safety considerations
Although the 8030A has been designed in accord-
ance with international safety standards, the fol-
lowing warnings and cautions should be observed
to ensure safe operation and to maintain the loud-
speaker under safe operating conditions:
• Servicing and adjustment must only be
performed by qualified service personnel. The
loudspeaker must not be opened.
• Do not use this product with an unearthed
mains cable as this may compromise
electrical safety.
• Do not expose the loudspeaker to water or mois-
ture. Do not place any objects filled with liquid,
such as vases on the loudspeaker or near it.
• This loudspeaker is capable of producing sound
pressure levels in excess of 85 dB, which may
cause permanent hearing damage.
• Free ow of air behind the loudspeaker is nec-
essary to maintain sufficient cooling. Do not
obstruct airflow around the loudspeaker.
• Note that the amplifier is not completely discon-
nected from the AC mains service unless the
mains power cord is removed from the amplifier
or the mains outlet.
Guarantee