5
Figure 5 — Oil Filter and Drain Plug
2. When the oil is drained, install and tighten the oil
drain plug.
3. If the engine is equipped with an oil filter, use
the following instructions:
A. Place a suitable container beneath the oil
filter and turn the filter counterclockwise to
remove the filter.
B. Coat the gasket of a new filter with engine oil.
Turn the new filter clockwise until the gasket
contacts the filter adapter, then tighten an
additional 3/4 turn.
4. Remove the oil fill plug and insert a clean funnel
into the plug opening. Fill the crankcase with the
recommended oil. The crankcase oil capacity is
about 46 oz. (1350 ml) without the oil filter. With
the filter, the oil capacity is 51 oz. (1500 ml).
POUR SLOWLY.
5. When the crankcase is filled to the proper level,
install and tighten the oil fill plug. Start engine to
fill oil filter, recheck/correct oil level.
SERVICING THE AIR CLEANER
This engine’s air cleaner is one of the most important
areas to maintain. The engine will not run properly
and may get damaged if it is run with a dirty air
cleaner system.
Clean or replace the paper air filter (Figure 6) every
50 hours of operation or once a year, whichever
comes first. Clean or replace the filter more often if
the engine is operated under dusty or dirty condi-
tions. Clean the foam pre-filter every 25 hours of
operation, or sooner under dusty or dirty condi-
tions.
Never run this equipment without the complete
air cleaner system installed on the engine. This
could result in premature wear to the engine.
Use the following instructions to clean or replace
the air cleaner components.
1. Loosen the two screws on the air cleaner cover.
Remove the air cleaner cover (Figure 6).
Figure 6 - Removing the Air Cleaner Cover
Foam Pre-filter
may stick to cover.
2. Remove the paper air filter and the foam pre-fil-
ter from the air cleaner cover (Figure 7).
Figure 7 - Air Cleaner Components
3. To clean or replace the foam pre-filter:
A. Wash the pre-filter in soapy water.
B. Squeeze the pre-filter dry with a clean cloth.
DO NOT TWIST.
NOTE:
Section 3 — Maintenance
GH - 410 Engine
Oil Filter
Drain Plug

Other manuals for Generac Power Systems GH-410

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Generac Power Systems GH-410 and is the answer not in the manual?

Generac Power Systems GH-410 Specifications

General IconGeneral
BrandGenerac Power Systems
ModelGH-410
CategoryEngine
LanguageEnglish

Related product manuals