Maintenance
16 Owner’s Manual for 7.5 kW PowerPact™
Service Schedule
NOTE: Contact an Independent Authorized Service Dealer or visit www.generac.com for additional information on
replacement parts.
Table 4-1. Service Maintenance Schedule
System Component Procedure Frequency
X = Action
* = Notify dealer if repair is needed Inspect Change Clean
W = Weekly
M = Monthly
Y = Yearly
Fuel
Fuel lines and connections X M
Lubrication
Oil level X M or 24 hours of continuous operation
Oil X 6 M or 100 hours of operation **
Enclosure louvers X X W
Battery
Remove corrosion; ensure dryness X X Y
Clean and tighten battery terminals X X Y
Check charge state X X Y
Electrolyte level (unsealed batteries only)* X X Every 6 M
Engine and mounting
Air cleaner
XXX
3 M / 50 hours - clean
1 Y / 300 hours - replace
Spark plug
XX
6 M or 100 hours - inspect
1 Y or 300 hours - change
Valve clearance X 1 Y or 300 hours***
General condition
Vibration, noise, leakage * X M
Contact the nearest Independent Authorized Service Dealer for assistance if necessary.
* Contact the nearest Independent Authorized Service Dealer for assistance if necessary.
** Change oil after the first 20 hours of operation or 1 month. Continue to check at intervals of 100 hours or 6 months, whichever occurs first. Severe duty oil drain
intervals: In cold weather conditions (ambient below 40 ºF [4.4 ºC]) change engine oil every 6 months or 50 hours of operation to prevent accumulation of water in
the oil. If the unit will be operated continuously in hot ambient conditions (ambient above 85 ºF [29.4 ºC]) or operation in an extremely dusty or dirty environment
change the engine oil every 3 months or 50 hours of operation to prevent oil breakdown.
*** Check valve clearance after the first 20 hours of operation. Continue to check at intervals of 300 hours.

Table of Contents

Other manuals for Generac Power Systems PowerPact 7.5 kW

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Generac Power Systems PowerPact 7.5 kW and is the answer not in the manual?

Generac Power Systems PowerPact 7.5 kW Specifications

General IconGeneral
BrandGenerac Power Systems
ModelPowerPact 7.5 kW
CategoryPortable Generator
LanguageEnglish

Related product manuals