Owner’s Manual for Portable Generator 21
Failure Description Fault Code
TPS high, open circuit or 5v, 12v short circuit P0123
TPS low, to 0V short circuit P0122
Cylinder temp high, open circuit or 5V, 12Vshort circuit P0118
Cylinder temp low, to 0V short circuit P0117
Air temp high, open circuit or 5V, 12Vshort circuit P0113
Air temp low, 0Vshort circuit P0112
System Voltage Low P0562
System Voltage High P0563
Cylinder Temperature High P0217
Barometric Pressure Sensor Failure P0226
Oil Pressure Abnormally Low P0524
Injection 1 open circuit P0201
Injection 1 to 0V short circuit P0261
Injection 1 overcurrent P0262
Fuel pump open circuit P0627
Fuel pump to 0V short circuit P0628
Fuel pump overcurrent P0629
Ignition 1 open circuit P2300
Ignition 1 overcurrent P2301
ECU Internal Failure P0606
Crankshaft Position Sensor Failure P0336
ECU Reset P1600
Engine Over speed Failure P0219
AC current sensor open circuit failure P1500
AC current sensor to ground short circuit failure P1501
AC current sensor to 5Vshort circuit failure P1502
Stepper Motor Binding P2101

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Generac Power Systems XT8500EFI and is the answer not in the manual?

Generac Power Systems XT8500EFI Specifications

General IconGeneral
BrandGenerac Power Systems
ModelXT8500EFI
CategoryPortable Generator
LanguageEnglish

Related product manuals