OPERATING INSTRUCTIONS
ALWAYS TURN ON THE DUST COLLECTOR BEFORE STARTING YOUR DUST PRODUCING MACHINE AND ALWAYS STOP THE
DUST PRODUCING MACHINE BEFORE TURNING OFF THE DUST COLLECTOR.
BEFORE STARTING
1. To minimize airborne dust make sure that all hoses, fittings and clamps are secure and airtight.
2. For maximum system efficiency, make sure a cover is installed on any unused hose inlet openings.
3. Never operate the machine without the filter bag or cartridge and the collection bag properly installed.
BASIC INSTRUCTIONS
The MODEL 10-110 & 10-110CF Dust Collector has been designed to capture, remove, and collect non-
metallic dust and wood dust around the workshop and from woodworking machinery.
THE SOUND LEVEL OF THIS MACHINE IS RATED AT APPROXIMATELY 80-90 DB DURING OPERATION. MAKE SURE THAT ADEQUATE
HEARING PROTECTION IS USED AND THAT THE OVERALL SOUND LEVEL WITHIN THE WORKING ENVIRONMENT IS TAKEN INTO
CONSIDERATION.
ON/OFF SWITCH
The model 10-110 & 10-110CF is equipped with a simple
“rocker style” On/Off switch featuring a removable lock
out safety key.
To prevent unauthorized use or unintentional start-up,
remove the safety key and store it in a safe place when-
ever the dust collector is not in use.
To start the dust collector, insert the safety key and pull up
the switch. To stop the machine, push down on the power
switch.
POWER ON
POWER OFF
SAFETY KEY
(PREVENTS START-UP
WHEN REMOVED)
MAKE SURE THE SWITCH IS IN THE “OFF” POSITION BEFORE PLUGGING IN THE POWER CORD.
REMOVE THE SWITCH KEY WHENEVER THE DUST COLLECTOR IS NOT IN USE. PLACE IT IN A SAFE PLACE AND OUT OF
THE REACH OF CHILDREN.
11
This machine operates on 220 V single phase power (M1 model only); if you suspect any electrical problems call
a qualified electrician to do the verification of the electrical circuit or the machine. If you need further help with your
dust collector contact your General® International distributor or call our Technical Support at (514) 326-1161.
MAKE SURE THE SWITCH IS IN THE «OFF» POSITION AND UNPLUG THE UNIT FROM THE POWER SOURCE BEFORE PER-
FORMING ANY MAINTENANCE.
MAINTENANCE & SERVICING
All bearings are sealed and permanently lubricated. No further lubrication is needed.
Periodically inspect all hardware, fittings and fasteners that may have loosened due to vibration - retighten
as needed.
Keep the outside of the unit clean and wipe off excessive dust or dirt with a dry rag.
Clean filters (
bag on 10-110 or cartridge on 10-110CF) on a regular basis and replace as needed.
Periodically inspect inside all pipes, fittings, blast gates, and connectors for accumulated dust build-up
or other obstructions and clean as needed. Remove sections and vacuum or manually remove debris as
needed.
Check and if necessary replace all damaged parts or components.
Do not operate with a damaged filter bag or canister - replace damaged filter immediately.
Periodically inspect the power cord and plug for damage. If necessary replace the power cord and plug
at the first signs of visible damage.
Use only recommended parts and accessories. The use of parts or accessories NOT recommended by
GENERAL® INTERNATIONAL may result in a risk of injury or damage to the machine.