Page #16 background imageLoading...
Page #16 background image
16
UK
BE24
Description
Position Value Type
7 - PROTECTION FUSES
10A
F
F1
Protects battery power circuit.
3,15A
F
F2
Protects external accessories, electric lock and flashing light.
8A
F
F3
Protects the circuit board.
8 - WARNING LEDs
Description
Position
Colour
Signal
L1
GREEN
START
Comes on when the START control is activated from the terminal board or the receiver.
L2
GREEN
PED
Comes on when the PED control is activated from the terminal board or the receiver.
L3
RED
PHOTO1
Always on. Comes off when the contact of terminal PHOTO 1 is opened.
L4
RED
PHOTO2
Always on. Comes off when the contact of terminal PHOTO 2 is opened.
L5
RED
SAFETY
Always on. Comes off when the resistance value of terminal SAFETY is wrong.
L6
RED
RX
Always off, comes on when LEARN button is pressed.
L7
BLUE
INFO
0,2s ON 0,2 OFF
The control board is locked, it’s necessary to execute a new travel
learning procedure.
30s ON
The control board is in pre-learning phase, aftre pressing MEMO
button.
0,2s ON-4s OFF
During sleep time, the control board is set to work with KUDA
operator.
During sleep time, the control board is set to work with BL240
operator.
0,2s ON - 0,2s OFF
0,2s ON - 4s OFF
2A
F
F4
Protects the transformer.
Motor 1 encoder error, travel learning procedure failed.
1s OFF - 0,6s ON - 1s OFF
X2
Motor 2 encoder error, travel learning procedure failed.
1s OFF - 0,6s ON - 0,6s OFF
0,6s ON - 1s OFF
X2