.49..48.
10. Specifications
Dimensions (W*H*D)
Weight
647*629*252mm
45kg
3/N/PE, 220/380, 230/400
Max. DC input voltage (Volts)
MPPT voltage range (Volts)
Max. input current (Amps)
MPPT number/Max input strings number
Rated grid voltage (Volts)
Rated grid output current (Amps)
Max. output current (Amps)
Power Factor (at rated output power)
Max.efficiency
EU efficiency
Model
Topology
Self consumption (night)
Operating ambient temperature range
Relative humidity
Ingress protection
Cooling concept
Max.operation altitude
AC connection
Grid connection standard
DC connection
1100
3*26
3*40
3/6
0.8leading~0.8lagging
50/60
98.8%
98.3%
Transformerless
<1W
-25℃.. .+60℃
0~100%
IP65
Natural convection
4000m
Display
Communication connections
Warranty
Rated output power (Watts)
Max. output power (Watts)
Max. apparent output power (VA)
MC4 connector
OT Terminal
LCD, 2×20 Z
RS485, Optional: Wifi, GPRS
5 years (extand to 20 years)
600
25000
27500
27500
38.0/36.1
41.8
THDi (at rated output power)
<3%
Start-up voltage (Volts)
Max short circuit input current (Amps)
Rated DC voltage (Volts)
Rated grid frequency (Hertz)
200...1000
180
VDE-A R-N 4105, VDE V 0124, VDE V 0126-1-1,
UTE C15-712-1, NRS 097-1-2, G98, G99,
EN 50549-1/-2, RD 1699, UNE 206006,
UNE 206007-1, IEC61727,DEWA
Solis-25K-5G
Safty/EMC standard
IEC 62109-1/-2, I EC62116 & EN 61000-6-2/-4
10. Specifications
Dimensions (W*H*D)
Weight
647*629*252mm
45kg
3/N/PE, 220/380, 230/400
Max. DC input voltage (Volts)
MPPT voltage range (Volts)
Max. input current (Amps)
MPPT number/Max input strings number
Rated grid voltage (Volts)
Rated grid output current (Amps)
Max. output current (Amps)
Power Factor (at rated output power)
Max.efficiency
EU efficiency
Model
Topology
Self consumption (night)
Operating ambient temperature range
Relative humidity
Ingress protection
Cooling concept
Max.operation altitude
AC connection
Grid connection standard
DC connection
1100
3*26
3*40
3/6
0.8leading~0.8lagging
50/60
98.8%
98.3%
Transformerless
<1W
-25℃.. .+60℃
0~100%
Natural convection
4000m
Display
Communication connections
Warranty
Rated output power (Watts)
Max. output power (Watts)
Max. apparent output power (VA)
MC4 connector
LCD, 2×20 Z
5 years (extand to 20 years)
600
30000
33000
33000
45.6/43.3
50.2
THDi (at rated output power)
<3%
Start-up voltage (Volts)
Max short circuit input current (Amps)
Rated DC voltage (Volts)
Rated grid frequency (Hertz)
200...1000
180
VDE-AR-N 4105, VDE V 0124, VDE V 0126-1-1,
UTE C15-712-1, NRS 097-1-2, G98, G99,
EN 50549-1/-2, RD 1699, UNE 206006,
UNE 206007-1, IEC61727,DEWA
Solis-30K-5G
Safty/EMC standard
IEC 62109-1/-2, I EC62116 & EN 61000-6-2/-4
OT Terminal
RS485, Optional: Wifi, GPRS
IP65